To compensate for fluctuation of the weather data (which may cause 
the weather alarm to ring constantly if the measured reading is close to 
the alarm level), a hysteresis function has been implemented for each 
weather alarm.  
 
For example, if the high temperature alarm is set to 77°F and the 
temperature reaches 77°F, the alarm will be activated. If the 
temperature then drops to 76.8°F (a change of less than 1.8°F) and 
then increases to 77°F again, the data will blink, but no alarm will be 
activated.  
The temperature would have to drop below 75.2°F (with a pre-set hysteresis of 1.8°F) so that the alarm 
can be produced again. Hysteresis values for the various weather data types are given in the table. 
Note: The temperature or humidity data will keep flashing even after the weather alarm has been 
switched off by a button press. The flashing value indicates that the current weather condition is out of the 
pre-set weather alarm limit(s). 
 
DISPLAY MODES 
 
MODE 1 
 
Press and release the SET button to toggle between Mode 1 and Mode 2 display: 
•  Pressure history graph displays 24 hour history 
•  Wind speed displayed in the wind section 
 
MODE 2 
 
Press and release the SET button to toggle between Mode 1 and Mode 2 display: 
•  Pressure history graph displays 72 hour history 
•  Wind gust displayed in the wind section 
 
DATE OR SECONDS DISPLAY 
 
• 
Press the ▲/DATE button to toggle between display of the date or seconds 
•  H
old the ▲/DATE button until the station beeps to resync with sensors 
 
RAINFALL DISPLAY 
 
Press and release the 
▼/RAIN button to view: 
•  1-hour 
•  24-hour 
•  Past Week  
•  Past Month 
•  Total Rainfall   
 
Hold the 
▼/RAIN button until the station beeps to resync with the gateway. 
 
 
 
 
 
 
 
 
  
WE AT HER FORECAST  AND T ENDENCY 
Weather data 
Hysteresis 
Temperature 
1.8°F 
Humidity 
3% RH 
Pressure 
0.029 inHg 
Wind speed 
6.2 mph