c) Low Water/Freeze-Up Safety Shutdown
If the water supply is interrupted or a freeze-up condition occurs, the decrease in suction 
line temperature causes the suction temperature safety to open and shut down the 
icemaker. See the table below for suction temperature safety cut-out/cut-in temperatures.
Suction Temperature Safety
Cut-out
23.9°F±2.7°F (-4.5°C±1.5°C)
Cut-in 
29.0°F±2.7°F (-1.5°C±1.5°C)
(3W)
(external 
overload 
2.4~3.0A)
(internal)
(external)