Справочник Пользователя для Hoshizaki C-100BAF-ADDS

Скачать
Страница из 44
20
C. Diagnostic Charts
1. No Ice Production
Problem
Possible Cause
Remedy
[1] The icemaker will not 
start.
a) Power Supply
1. Off, blown fuse, or 
tripped breaker.
1. Turn on, replace, or reset.
2. Power cord 
unplugged.
2. Plug into outlet.
3. Loose connection.
3. Tighten.
4. Bad contacts.
4. Check for continuity and 
replace.
5. Not within 
specifications.
5. Refer to nameplate and 
correct.
b) Power Switch 
(Control Box)
1. "OFF" position.
1. Move to "ON" position.
2. Bad contacts.
2. Check for continuity and 
replace.
c) Suction Temperature 
Safety 
(Low Water/Freeze-Up 
Safety)
1. Open due to water 
supply cut-off.
1. Check water supply, 
water filters, water inlet 
strainer-washer, float, and 
water valve.
2. Open due to 
evaporator freeze-up 
(gear motor not 
operating).
2. Check gear motor 
operation.
3. Bad contacts.
3. Check for continuity and 
replace.
d) Bin Control Thermostat 
Assembly (with 
integrated heater)
1. Open with bin filled 
with ice.
1. Remove ice.
2. Ambient temperature 
too cool.
2. Increase ambient 
temperature.
3. Bulb out of position.
3. Place in position.
4. Bad contacts.
4. Check for continuity 
and replace. See 
"V.F. Removal and 
Replacement of Bin 
Control Thermostat 
Assembly." 
5. Bad thermostat 
heater.
5. Check and replace. 
See "V.F. Removal 
and Replacement of 
Bin Control Thermostat 
Assembly." 
e) Gear Motor Protector 
(External Overload) 
(2.4~3.0A)
1. Tripped.
1. Press switch on control 
box to reset. Check 
supply voltage, gear 
motor amperage, gear 
motor bearings, and 
auger bearings (see 
"V.C.1. Upper Bearing 
Wear Check"). Check for 
evaporator freeze-up.