Chapter 2
Function Reference — Config_ATrig_Event_Message
NI-DAQ FRM for PC Compatibles
2-70
©
National Instruments Corporation
Figure 2-3. Analog Trigger Event
Config_ATrig_Event_Message
is a high-level function for NI-DAQ event messaging.
Because this function uses the current inputRange and polarity settings to translate
trigLevel and windowSize into binary units, you should not call
trigLevel and windowSize into binary units, you should not call
AI_Configure
and change
these settings after you have called
Config_ATrig_Event_Message
. For more information
on NI-DAQ event messaging, see the low-level function
Config_DAQ_Event_Message
.
P
N
Time
trigLevel
+ windowSize
trigLevel
- windowSize
trigLevel
P: positive trigger point
N: negative trigger point
N: negative trigger point