Справочник Пользователя для National Instruments 321645c-01

Скачать
Страница из 554
Chapter 2
Function Reference — DAQ_Clear
©
 National Instruments Corporation
2-117
NI-DAQ FRM for PC Compatibles
DAQ_Clear
Format
status = DAQ_Clear (deviceNumber)
Purpose
Cancels the current DAQ operation (both single-channel and multiple-channel scanned) and 
reinitializes the DAQ circuitry.
Parameters
Input    
Using This Function
DAQ_Clear
 turns off any current DAQ operation (both single-channel and multiple-channel), 
cancels the background process that is handling the data acquisition, and clears any error flags 
set as a result of the data acquisition. NI-DAQ then reinitializes the DAQ circuitry so that 
NI-DAQ can start another data acquisition.
Note
If your application calls 
DAQ_Start
SCAN_Start
, or 
Lab_ISCAN_Start
always make sure that you call 
DAQ_Clear
 before your application terminates and 
returns control to the operating system. Unpredictable behavior can result unless 
you make this call (either directly, or indirectly through 
DAQ_Check
Lab_ISCAN_Check
, or 
DAQ_DB_Transfer
).
Name
Type
Description
deviceNumber
i16
assigned by configuration utility