Get_DAQ_Device_Info
Format
status = Get_DAQ_Device_Info (deviceNumber, infoType, infoValue)
Purpose
Allows you to retrieve parameters pertaining to the device operation.
Parameters
Input 
Output 
Parameter Discussion
The legal range for the infoType is given in terms of constants that are defined in the header 
file. The header file you should use depends on the language you are using:
C programmers—
NIDAQCNS.H
 (
DATAACQ.H
 for LabWindows/CVI)
BASIC programmers—
NIDAQCNS.INC
Pascal programmers—
NIDAQCNS.PAS
infoType indicates which parameter to retrieve. infoValue reflects the value of the parameter. 
infoValue is given either in terms of constants from the header file or as numbers, as 
appropriate.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
infoType
u32
type of information to retrieve