Справочник Пользователя для National Instruments 321645c-01
Chapter 2
Function Reference — GPCTR_Set_Application
NI-DAQ FRM for PC Compatibles
2-216
©
National Instruments Corporation
application can be one of the following.
Table 2-31. Descriptions for application
Group
Application
Description
Simple
Counting
and Time
Measurement
Counting
and Time
Measurement
ND_SIMPLE_EVENT_CNT
Simple event counting
ND_SINGLE_PERIOD_MSR
Simple single period measurement
ND_SINGLE_PULSE_WIDTH_MSR
Simple single pulse-width
measurement
measurement
ND_TRIG_PULSE_WIDTH_MSR
Pulse-width measurement you can
use for recurring pulses
use for recurring pulses
ND_TWO_SIGNAL_EDGE_SEPARATION_
MSR
Pulse-width measurement for
signals on two separate gates
(6602 and 455X devices only)
signals on two separate gates
(6602 and 455X devices only)
Simple Pulse
and Pulse
Train
Generation
and Pulse
Train
Generation
ND_SINGLE_PULSE_GNR
Generation of a single pulse
ND_SINGLE_TRIG_PULSE_GNR
Generation of a single triggered
pulse
pulse
ND_RETRIG_PULSE_GNR
Generation of a retriggerable
single pulse
single pulse
ND_PULSE_TRAIN_GNR
Generation of pulse train
ND_FSK
Frequency Shift-Keying
Buffered
Counting
and Time
Measurement
Counting
and Time
Measurement
ND_BUFFERED_EVENT_CNT
Buffered, asynchronous event
counting
counting
ND_BUFFERED_PERIOD_MSR
Buffered, asynchronous period
measurement
measurement
ND_BUFFERED_SEMI_PERIOD_MSR
Buffered, asynchronous semi-period
measurement
measurement
ND_BUFFERED_PULSE_WIDTH_MSR
Buffered, asynchronous pulse-width
measurement
measurement
ND_BUFFERED_TWO_SIGNAL_EDGE_
SEPARATION_MSR
Buffered, asynchronous pulse-width
measurement for signals on separate
gates (6602 and 455X devices only)
measurement for signals on separate
gates (6602 and 455X devices only)
_CNT
= Counting
_MSR
= Measurement
_GNR