Chapter 2
Function Reference — GPCTR_Set_Application
©
 National Instruments Corporation
2-221
NI-DAQ FRM for PC Compatibles
measure a time interval between 100 ns and 0.8 s long.For the 6602 and 455X devices with 
counter width 32 bits, you can measure a time interval between 100 ns and 214 s long.
Figure 2-16 shows one possible scenario of a counter used for 
ND_SINGLE_PULSE_WIDTH_MSR
 after the following programming sequence:
GPCTR_Control(deviceNumber, gpctrNum, ND_RESET)
GPCTR_Set_Application(deviceNumber, gpctrNum, 
ND_SINGLE_PULSE_WIDTH_MSR)
GPCTR_Control(deviceNumber, gpctrNum, ND_PROGRAM)
In Figure 2-16, the following behavior is present:
Gate is the signal present at the counter gate input.
Source is the signal present at the counter source input.
Count is the value you would read from the counter if you called the 
GPCTR_Watch
 
function with entityID =
ND_COUNT
. The different numbers illustrate behavior at 
different times.
Count Available is the value you would read from the counter if you called the 
GPCTR_Watch
 function with entityID =
ND_COUNT_AVAILABLE
. The different values 
illustrate behavior at different times. 
Figure 2-16.  Single Pulse Width Measurement
Use the 
GPCTR_Watch
 function with entityID = 
ND_ARMED
 to monitor the progress of the 
counting process. This measurement completes when entityValue becomes 
ND_NO
. When 
the counter is no longer armed, you can retrieve the counted value by using 
GPCTR_Watch
 
with entityID = 
ND_COUNT
, as shown in the following example code:
Create u32 variable count_available.
Create u32 variable counted_value.
repeat
{
0
1
NO
NO
2
Gate
Source
Count
Count Available
Measured
Interval
 YES
YES
2
2
2
2
2