Справочник Пользователя для National Instruments 321645c-01

Скачать
Страница из 554
Chapter 2
Function Reference — SCXI_Get_Module_Info
©
 National Instruments Corporation
2-339
NI-DAQ FRM for PC Compatibles
24:
SCXI-1162HV.
28:
SCXI-1163R.
30:
SCXI-1102.
32:
SCXI-1141.
38:
SCXI-1200.
40:
SCXI-2400.
42:
VXI-SC-1102
44:
VXI-SC-1150
68:
SCXI-1120D.
Any other value returned in the modulePresent parameter indicates that an unfamiliar 
module is present in the given slot.
operatingMode indicates whether the module present in the given slot is being operated in 
Multiplexed or Parallel mode. Refer to Chapter 13, SCXI Hardware, in the DAQ Hardware 
Overview Guide 
for an explanation of each operating mode. If the slot is empty, 
operatingMode is meaningless.
0:
Multiplexed operating mode.
1:
Parallel operating mode.
DAQdeviceNumber is the device number of the DAQ device in the PC that is cabled 
directly to the module present in the given slot. If the slot is empty, DAQdeviceNumber 
is meaningless.
0:
No DAQ device is cabled to the module.
n,
where n is the device number of the DAQ device cabled to the module.
If the moduleSlot contains an SCXI-1200, DAQdeviceNumber is the logical device number 
of the SCXI-1200. If the moduleSlot contains an SCXI-2400, DAQdeviceNumber is 0.
Note
C Programmers—modulePresentoperatingMode, and DAQdeviceNumber are 
pass-by-reference parameters.