Chapter 2
Function Reference — AI_Configure
©
 National Instruments Corporation
2-7
NI-DAQ FRM for PC Compatibles
1:
Referenced Single-Ended (RSE) configuration (used when the input signal does 
not have its own ground reference. The negative input of the instrumentation 
amplifier is tied to the instrumentation amplifier signal ground to provide one).
2:
Nonreferenced Single-Ended (NRSE) configuration (used when the input signal 
has its own ground reference. The ground reference for the input signal is 
connected to AISENSE, which is tied to the negative input of the instrumentation 
amplifier).
inputRange is the voltage range of the analog input channels. polarity indicates whether the 
ADC is configured for unipolar or bipolar operation:
0:
Bipolar operation (default value).
1:
Unipolar operation.
Table 2-1 shows all possible settings for inputModeinputRange, and polarityinputMode 
is independent of inputRange and polarity. In this table, italic text denotes default settings.
Table 2-1.  Parameter Settings for 
AI_Configure
Device
Possible 
Values for 
inputMode
Analog Input Range
Software 
Configurable
inputRange
polarity
Resulting 
Analog 
Input 
Range
AT-MIO-64F-5, 
AT-MIO-16F-5, 
12-bit E Series
0, 1, 2
ignored
unipolar
0 to +10 V
Yes
ignored
bipolar
–5 to +5 V
AT-MIO-16X, 
16-bit E Series, 
PCI-6110E, 
PCI-6111E
0, 1, 2
ignored
unipolar
0 to +10 V
Yes 
ignored
bipolar
–10 to +10 V
MIO-16 and 
AT-MIO-16D
0, 1, 2
10
unipolar
0 to +10 V
No
10
bipolar
–5 to +5 V
20
bipolar
–10 to +10 V
Lab-PC+
0, 1, 2
ignored
unipolar
0 to +10 V
No
ignored
bipolar
–5 to +5 V
1200 and 
1200AI Devices
0, 1, 2
ignored
unipolar
0 to +10 V
Yes
ignored
bipolar
–5 to +5 V