Chapter 2
Function Reference — Set_DAQ_Device_Info
©
 National Instruments Corporation
2-389
NI-DAQ FRM for PC Compatibles
Set_DAQ_Device_Info
Format
status = Set_DAQ_Device_Info (deviceNumber, infoType, infoValue)
Purpose
This function can be used to change the data transfer mode (interrupts and DMA) for certain 
classes of data acquisition operations, some settings for an SC-2040 track-and-hold accessory 
and an SC-2043-SG strain-gauge accessory, as well as the source for the CLK1 signal on the 
DAQCard-700. Refer to the Using This Function section to determine which settings can be 
changed for your device.
Parameters
Input
Parameter Discussion
Legal ranges for the infoType and infoValue are given in terms of constants that are defined 
in a header file. The header file you should use depends on which of the following languages 
you are using:
C programmers—
NIDAQCNS.H
 (
DATAACQ.H
 for LabWindows/CVI)
BASIC programmers—
NIDAQCNS.INC
 (Visual Basic for Windows programmers should 
refer to the 
 section in Chapter 1, 
, for more information.)
Pascal programmers—
NIDAQCNS.PAS
infoType indicates which parameter you want to change. Use infoValue to specify the 
corresponding new value.
Values that infoType accepts depend on the device you are using. The legal range for 
infoValue depends on the device you are using and infoType
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
infoType
u32
parameter you want to modify
infoValue
u32
new value you want to assign to the parameter 
specified by infoType