INSTALLATION, OPERATION AND CARE OF 
MEDIUM DUTY GAS HOTPLATES 
 
GENERAL 
 
Gas Countertop Hotplates are designed for commercial use only and feature fast, efficient 
gas heat.  Each burner is controlled by an adjustable gas valve. Cast grates and burners 
are easily removed for cleaning when cool. 
 
 
Model 
Number Of Burners 
BTU/hr Input Rating 
VCRH12 / WCRH12 
50,000 
VCRH24 / WCRH24 
100,000 
VCRH36 / WCRH36 
150,000 
 
 
 
 
 
 
 
 
INSTALLATION 
UNPACKING 
 
Immediately after unpacking, check for possible shipping damage.  If the hotplate is found 
to be damaged, save the packaging material and contact the carrier within 15 days of 
delivery. 
 
 
LOCATION 
The installation location must be kept free and clear of combustibles.  Do not obstruct the 
flow of combustion and ventilation air. DO NOT install the hotplate adjacent to open 
burners or fryers. 
Sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilating system and for combustion of the gas burners.  Do not 
obstruct the air flow into and around the hotplate. Position the hotplate in its final 
location.  Check that there are sufficient clearances to service the hotplate and to make 
the required gas supply connection(s).  Provide 24" clearance at the front for cleaning, 
maintenance, service and proper operation. 
   
Minimum clearances to combustible construction are 9" to the back and 10" to the sides. 
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides.