Installation instructions
Do not install the DA 8-2 directly
next to a gas hob.
This extractor is designed for installa-
tion between Combiset appliances. 
It should always be installed between
two appliances, such as the grill and
deep fryer.
Prepare the countertop cut-out as il-
lustrated.
Dimension ”B“ will vary depending
on how many combisets are in-
stalled. The following chart gives
dimension ”B“ for a variety of 2 zone
(ie KM 88-2) and 4 zone (ie KM 93-2)
combinations.
2
3
/
16
˝
19
5
/
16
˝
2
3
/
16
˝
Depth
 (in 
mm)
Width
(= Dimen-
sion B)
(in mm)
2 zone Combiset
1 combiset
2 combisets
3 combisets
4 combisets
5 combisets
490
490
490
490
490
265
558
851
1144
1437
4 zone Combiset
1 combisets
2 combisets
3 combisets
490
490
490
560
1143
1728
Combination
One 2 zone 
+ one 4 zone
Two 2 zone 
+ one 4 zone
Three 2 zone 
+ one 4 zone
One 2 zone 
+ two 4 zone
Two 2 zone 
+ two 4 zone
490
490
490
490
490
851
1143
1437
1436
1729
Extractor (e.g. DA 8-2)
For installation between two appliances:
Dimension
 
B
 increases by 90 mm.
For installation at the end of a combination:
Dimension
 
B
 increases by 98 mm.
Installation instructions