4. Repeat steps 1-3 for the underside of the top of the cabinet.
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the 
wall:
1. Make 2 lines by measuring 
³⁄₈" (0.9 cm) and 3⁷⁄₈" (9.8 cm) 
down from underside of cabinet and mark on the centerline 
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline 
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the 
wall for the vent.
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm) 
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4
¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout 
on the underside of cabinet bottom:
1. Mark lines 
¹⁄₂" (1.3 cm) and 4³⁄₄" (12.1 cm) from the back wall 
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline 
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for 
vent. 
To make a circular vent opening on the underside of the 
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 
5" (12.7 cm) from the back wall on the underside 
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a 
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Style 3 - Cut Openings for 7" (17.8 cm) Round Vent
To make a circular vent openings on the underside of the 
cabinet top and bottom:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 
5" (12.7 cm) from the back wall on the underside 
of the top and bottom of cabinet.
3. Use a compass or a circle template to draw a circle with a 
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall. 
Complete venting system according to the selected venting 
method. See “Venting Requirements” section. 
2. Use caulking to seal exterior wall or roof opening around the 
cap.
5
¹
/
"
(13.3 cm)
5
¹
/
"
(13.3 cm)
*4
³⁄₄
"
(12.1 cm)
*From wall, not cabinet frame
Cabinet cutouts
*
¹⁄₂
" (1.3 cm)
³⁄₈
"
3⁷⁄₈
"
Cabinet
front
(1.0 cm)
(9.8 cm)
5
¹⁄₄
"
(13.3 cm)
Centerline
5
¹⁄₄
"
(13.3 cm)
5
¹
/
"
(13.3 cm)
5
¹
/
"
(13.3 cm)
*4
³⁄₄
"
(12.1 cm)
*From wall, not cabinet frame
*
¹⁄₂
" (1.3 cm)
Circular vent opening
Cabinet 
cutouts
*From wall, not
 cabinet frame
*5" 
(12.7 cm)
¹
/
" (18.4 cm) diam.
cabinet cutouts
*From wall, not
 cabinet frame
*5" 
(12.7 cm)