8
10005360
LHE Series Natural Vent Insert
Installer must attach red warning plate 
with screws supplied with the gas fireplace 
insert to the inside of the firebox of the 
fireplace into which the gas fireplace insert 
is installed.
Cutting any sheet metal parts of the fire-
place, in which the gas fireplace insert is 
to be installed, is prohibited.
If the factory-built fireplace has no gas 
access hole(s) provided, an access hole 
of 1¹⁄₂ (37.5 mm) or less may be drilled 
through the lower sides or bottom of the 
firebox in a proper workmanship-like man-
ner. This access hole must be plugged 
with a noncombustible insulation after the 
gas supply line has been installed.
Venting Installation
1.  The fireplace may be installed in and vented through 
any solid fuel fireplace that has a minimum fireplace 
opening 25¹⁄₄"W x 17¹⁄₂" H x 13¹⁄₂"D 
(641 x 438 x 343 
mm) 
for LHEC20 and LHER20 or 28³⁄₄"W x 21"H 
x 15¹⁄₂"D 
(730 x 533 x 394 mm) 
 for LHEC30 and 
LHER30 and has been installed in accordance with 
the National, Provincial/State and local building 
codes and is constructed of noncombustible 
materials.
2.  In order to gain minimum gas insert fireplace 
opening requirement, if the fire brick refractory is 
removed from a factory built fireplace, a minimum 
of 1/4" air space is required between the gas insert 
fireplace's outer casing and the inner wall of the 
factory built fireplace.
3.  In order to obtain the best performance, safety and 
efficiency for the gas insert fireplace, the LHEC30 
and LHER30 gas insert must be installed with an 
approved 4" diameter flue liner. The LHER20 and 
LHEC20 should be installed with an approved 3" 
diameter flue liner as per current CSA-B149.1 or 
National Fuel Gas Code ANSI Z223.1/NFPA 54.
4.  Any flue damper must be removed or blocked open.
5.  The chimney must be clean and in good working 
order and constructed of noncombustible materials.
6.  Make sure that all chimney cleanouts fit properly so 
air cannot leak into the chimney.
7.  Install the appliance without trim frame and make all 
gas fittings and electrical connections.
8.  Install the decorative trim frame. Please refer to the 
Frame Assembly instructions.
CAUTION:  Do not wire millivolt remote 
wall switch for gas fireplace to a 120v 
power supply.
PILO
T
THTP
TP
TH
FP382a
REMOTE SWITCH WIRING - NVC
1/03
SIT Valve
Thermopile
FP382a
Fig. 9a  On/Off switch or millivolt thermostat.
TPTH
TH
TP
FP1218
Remote switch
wiring
8/02
FP1218
Fig. 9b  On/Off switch wiring.
Honeywell Valve
Fig. 8  For left side installation, reverse switch position in 
bracket.
FP1331
on/off switch
4/03
FP1331
WARNING
Some factory-built fireplaces have air passages 
on face of fireplace for zero clearance capabilities. 
Under no circumstances should these passages 
be blocked.
FP1330
Switch assy
4/03
Left Side Installation
Right Side Installation
On/Off 
Switch As-
sembly
Wiring from 
Millivolt Gas 
Valve
Fig. 7   Insert ON/OFF switch with wiring assembly into 
bracket switch.
On/Off 
Switch As-
sembly
FP1330