Справочник Пользователя для IBM 6347

Скачать
Страница из 252
Diagnostic Error Code
FRU/Action
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1.
Go to the
Undetermined problems
section
2.
Flash the system and re-test
3.
Replace component under function test
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
1.
Check fans
2.
Check Power supply
3.
Microprocessor
4.
System board
185-000-XXX
Asset Security Test Passed
1.
No action
185-XXX-XXX
Asset Security failure
1.
Flash system
2.
System board
185-278-XXX
Asset Security Chassis Intrusion
1.
Assure Asset Security Enabled
2.
C2 Cover Switch
3.
System board
201-000-XXX
System Memory Test Passed
1.
No action
201-XXX-XXX
System Memory error
1.
Replace the memory module called out
by the test
2.
System board
202-000-XXX
System Cache Test Passed
1.
No action
202-XXX-XXX
System Cache error
1.
Cache, if removable
2.
System board
3.
Microprocessor
206-000-XXX
Diskette Drive Test Passed
1.
No action
206-XXX-XXX
Diskette Drive error
1.
Diskette Drive Cable
2.
Check power supply voltages
3.
Diskette drive
4.
System board
215-000-XXX
CD-ROM Drive Test Passed
1.
No action
215-XXX-XXX
CD-ROM Drive error
1.
CD-ROM Drive Cable
2.
Check power supply voltages
3.
CD-ROM drive
4.
System board
217-000-XXX
Hard Disk Drive Test Passed
1.
No action
217-25X-XXX
217-26X-XXX
Hard Disk Drive (IDE) error
1.
Hard Disk Drive Cable
2.
Check power supply voltages
3.
Hard Disk drive (IDE)
4.
System board
88
Hardware Maintenance Manual