Справочник Пользователя для Furuno MU-155C

Скачать
Страница из 36
 
 
19
WARNING
Ensure battery polarity is correct.
Wrong polarity may cause the batteries to 
explode. 
Fuse replacement 
The fuse in the power cable protects the equipment from internal fault and overcurrent. If 
the fuse blows, find the cause before replacing it. If the fuse blows again after replacement, 
request service. 
 
Ship’s power source 
Rating of fuse 
12 VDC 
10A 
24 VDC 
5A 
 
 
Battery replacement 
The remote controller has two AA batteries. 
If the distance from which the remote 
controller can be operated has decreased, 
change the battery. 
 
Note: Replace all batteries together. Do 
not mix old and new batteries. 
 
 
5.2 Troubleshooting 
The table below provides troubleshooting procedures to use when no picture appears. If 
you cannot restore the picture, do not attempt to check inside the equipment – there are no 
user serviceable parts inside. Refer any work to a qualified technician. 
Troubleshooting table 
Reason for no picture 
Remedy 
Ship’s battery voltage too high 
Check battery voltage. 
Fuse has blown. 
Replace fuse. 
Cable between MU-155C and external 
equipment has loosened. 
Refasten cable. 
Power cable has loosened. 
Refasten cable. 
 
You can confirm which signals are currently input in the SYSTEM menu. 
 
 
 
 
 
 
 
 
 
SYSTEM menu 
RGB1   RGB2   DVI   VIDEO1   VIDEO2   VIDEO3   OSD   
SYSTEM
 
INFRARED REMOTE   A       A
DEFAULT RESET      NO 
 
 
   
INFORMATION 
RGB1  : 1280x1024  fH: 80KHz  fV: 75Hz 
RGB2  :  640x480 
fH: 31KHz  fV: 60Hz 
DVI    : NO SIGNAL
 
VIDEO1: NTSC 
VIDEO2: PAL 
VIDEO3: NO SIGNAL 
PROGRAM NO. ***** 
WARNING
Use the proper fuse.
Use of a wrong fuse can cause fire or
damage to the equipment.