Cold Drink Center (327/328) Operator’s Guide
August, 2003
Page 66
3280020
TEST THE CARBONATOR
This screen serves several functions. One is to test the refill capability of the car-
bonator pump. The second is to empty the carbonator before storage or shipping.  
The third function is to dispense still water.
1.
Press 
, then press 
 until the display shows 
CARB TEST
.
2.
Press 
 to test the carbonator.  The carbonator will dispense until it is 
empty, then it will refill.  As it fills, the display will show the refill time.  You 
can adjust the carbonator pump to set the refill time to 15 - 25 seconds.
3.
Press 
 to run non-carbonated water through the dispensing lines.
4.
Press 
 to empty the carbonator without refilling.  Before doing this, 
you should turn off water to the machine and dispense still water (see step 2
until the feeder cup is empty.
5.
CONTINUE.
COOLSAN OPERATION
1.
Remove the ice chute from the machine.
2.
Empty the waste pail and place it directly under the ice maker door using the 
hook provided.
3.
Press 
, then press 
 until the display shows 
COOL SAN
.
4.
Press and hold the 
 key. The display will briefly show "
CLEARING
" and 
three beeps will sound. Release the 
 key.
5.
Coolsan will empty the ice maker (approximately 3-5 minutes). The display 
will flash the "
DUMP ICE
" message transposed with the time left for the 
coolsan process to complete. All messages will flash between the current 
operation notification and the time left in the coolsan process. The operator 
may remove the pail when all the ice is visually removed from the hopper.