Листовка для Thecus 2TB Storage Server 250W Redundant PSU 1U4500R_4050
Модели
1U4500R_4050
81
RAID 1
RAID 1 mirrors all data from one hard disk drive to a second one hard disk drive,
thus providing complete data redundancy. However, the cost of data storage
thus providing complete data redundancy. However, the cost of data storage
capacity is doubled.
This is excellent for complete data security.
RAID 5
RAID 5 offers data security and it is best suited for networks that perform many
small I/O transactions at the same time, as well as applications that require data
security such as office automation and online customer service. Use it also for
security such as office automation and online customer service. Use it also for
applications with high read requests but low write requests.
RAID 5 includes disk striping at the byte level and parity information is written to
RAID 5 includes disk striping at the byte level and parity information is written to
several hard disk drives. If a hard disk fails the system uses parity stored on each
of the other hard disks to recreate all missing information.
of the other hard disks to recreate all missing information.
RAID 6
RAID 6 is essentially an extension of RAID level 5 which allows for additional fault
tolerance by using a second independent distributed parity scheme (dual parity)
tolerance by using a second independent distributed parity scheme (dual parity)
Data is striped on a block level across a set of drives, just like in RAID 5, and a
second set of parity is calculated and written across all the drives; RAID 6
second set of parity is calculated and written across all the drives; RAID 6
provides for an extremely high data fault tolerance and can sustain two
simultaneous drive failures.
simultaneous drive failures.
This is a perfect solution for mission critical applications.
RAID 10
RAID 10 is implemented as a striped array whose segments are RAID 1 arrays.
RAID 10 has the same fault tolerance as RAID level 1.
RAID 10 has the same overhead for fault-tolerance as mirroring alone. High I/O
RAID 10 has the same overhead for fault-tolerance as mirroring alone. High I/O
rates are achieved by striping RAID 1 segments.
Under certain circumstances, RAID 10 array can sustain up to 2 simultaneous
Under certain circumstances, RAID 10 array can sustain up to 2 simultaneous
drive failures
Excellent solution for applications that would have otherwise gone with RAID 1
but need an additional performance boost.
but need an additional performance boost.
JBOD
Although a concatenation of disks (also called JBOD, or "Just a Bunch of Disks") is
not one of the numbered RAID levels, it is a popular method for combining
multiple physical disk drives into a single virtual one. As the name implies, disks
multiple physical disk drives into a single virtual one. As the name implies, disks
are merely concatenated together, end to beginning, so they appear to be a
single large disk.
single large disk.
As the data on JBOD is not protected, one drive failure could result total data loss.
Stripe Size
The length of the data segments being written across multiple hard disks. Data is
written in stripes across the multiple hard disks of a RAID. Since multiple disks
written in stripes across the multiple hard disks of a RAID. Since multiple disks
are accessed at the same time, disk striping enhances performance. The stripes
can vary in size.
can vary in size.