Справочник Пользователя для Fujitsu MBA3147NC

Скачать
Страница из 138
A.1 
Setting Terminals (on NP model only)  
Table A.1 
CN2 setting terminal (on NP model drives only) 
Pin pair 
Setting item 
1 - 2 
3 - 4 
5 - 6 
7 - 8 
9 - 10 
Setting contents 
Open  Open  Open  (Open)
SCSI ID #0      (Common to 8-bit and 16-bit SCSI)  
Short  Open  Open  (Open)
SCSI ID #1      (Common to 8-bit and 16-bit SCSI) 
Open  Short  Open  (Open)
SCSI ID #2      (Common to 8-bit and 16-bit SCSI) 
Short  Short  Open  (Open)
SCSI ID #3      (Common to 8-bit and 16-bit SCSI) 
Open  Open  Short  (Open)
SCSI ID #4      (Common to 8-bit and 16-bit SCSI) 
Short  Open  Short  (Open)
SCSI ID #5      (Common to 8-bit and 16-bit SCSI) 
Open  Short  Short  (Open)
SCSI ID #6      (Common to 8-bit and 16-bit SCSI) 
Short  Short  Short  (Open)
SCSI ID #7      (Common to 8-bit and 16-bit SCSI) 
Open  Open  Open  Short 
SCSI ID #8      (16-bit SCSI only) 
Short  Open  Open  Short 
SCSI ID #9      (16-bit SCSI only) 
Open  Short  Open  Short 
SCSI ID #10    (16-bit SCSI only) 
Short  Short  Open  Short 
SCSI ID #11    (16-bit SCSI only) 
Open  Open  Short  Short 
SCSI ID #12    (16-bit SCSI only) 
Short  Open  Short  Short 
SCSI ID #13    (16-bit SCSI only) 
Open  Short  Short  Short 
SCSI ID #14    (16-bit SCSI only) 
SCSI ID
 
Short Short Short Short 
 
SCSI ID #15    (16-bit SCSI only) (*) 
 
 
 
 
Open  Write operation is enabled. (*) 
Write protect 
    
Short 
Write 
operation 
is 
disabled. 
 
Pin pair
 
Setting item 
11 - 12  13 - 14  15 - 16  23 - 24 
Setting contents 
Motor start mode 
Open 
 
 
 
Started by the START/STOP command 
 
Short 
 
 
 
Started by turning the power supply on (*) 
Force Narrow 
 
Open 
 
 
Width of 16-bit bus (*) 
 
 
Short 
 
 
Width of 8-bit bus 
Force Single Ended 
 
 
Open 
 
Follows DIFFSNS signal level on SCSI bus (*) 
  
 
Short 
 
Single-Ended 
mode 
Terminating power supply 
 
 
 
Open 
Does not supply terminating resistor power to SCSI BUS
 
 
 
 
Short 
Supply terminating resistor power to SCSI BUS (*) 
*  Setting at factory shipment 
 Note: 
 
See the description of Section 5.3 for details of the setting requirements and notes. 
118 