Справочник Пользователя для Silicon Image SSD-H16G(I)-3500

Скачать
Страница из 76
ATA R
EGISTERS
SSD-H
XXX
(I)-3500 D
ATA
 S
HEET
S
ILICON
S
YSTEMS
 P
ROPRIETARY
This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.
All unauthorized use and/or reproduction is prohibited.
3500H-03DSR
P
AGE
 16
F
EBRUARY
 2, 2009
ATA R
EGISTERS
D
ATA
 R
EGISTER
The Data register is a 16-bit register used to transfer data blocks between the
host and drive buffers. The register may set to 8-bit mode by using the Set
Features Command defined in 
E
RROR
 R
EGISTER
The Error register contains the error status, if any, generated from the last
executed ATA command. The contents are qualified by the ERR bit being set
in 
.
Table 18:  Error Register
Operation
D
7
D
6
D
5
D
4
D
3
D
2
D
1
D
0
Read
BBK
UNC
MC
IDNF
MCR ABRT TKNOF AMNF
Default 
Value
0
0
0
0
0
0
0
0
Bit(s)
Description
7
Bad Block Detected (BBK). 
Set when a bad block is detected.
6
Uncorrectable Data Error (UNC). 
Set when an uncorrectable error
is encountered.
5
Media Changed (MC). 
Set to 0.
4
ID Not Found (IDNF). 
Set when the sector ID is not found.
3
MCR (Media Change Request). 
Set to 0.
2
Aborted Command (ABRT). 
Set when a command is aborted due
to a drive error.
1
Track 0 Not Found (TKONF). 
Set when the execute drive
diagnostic command is executed.
Address Mark Not Found (AMNF). 
Set in the case of a general