Operation SE-F And SES-F
Frost tops are designed to maintain an even layer of frost to 
pleasantly display desserts and pies.  Once turned on, the 
compressor will run continuously.  The unit should be turned off 
overnight or when not in use.  
Since it takes time for frost to accumulate initially, the unit 
should be turned on approximately an hour before it is actually 
required.  Product should not be placed on the frost top prior to 
turning the unit on, because it may freeze to the surface of the 
unit.
Operation SE-HC And SES-HC
The hot and cold combination pans must be operated with 
water in the well.
Hot Operation
Fill well with a minimum of 4” of water. Place function switch 
in 
HOT position.  Turn thermostat dial to highest position and 
allow unit to warm up.  Then reset the thermostat to maintain 
the desired temperature. 
Never use anything more than plain water in the 
wells or tank.  Failure to observe this warning 
may result in personal injury or damage to the 
unit.
When operated at the highest temperature 
setting, the top of the unit will become very 
hot.  Staff and customers using the equipment 
should be informed about this.
To turn unit off, simply move the function switch to 
OFF 
position.  Drain water and allow unit to cool before cleaning or 
switching to cold operation.
Cold Operation
Simply place the function switch to the 
COLD position.  The 
compressor controller has been factory set and no temperature 
adjustment should be necessary.  When the cold pan is used 
with ice, use perforated bottoms.  These will allow ice to melt 
properly.
Switching from Hot to Cold Operation
Follow the following procedure:
1) 
Place the function switch in the 
OFF position 
and drain off hot water.
2) 
Allow the unit to cool until it can be safely 
cleaned.
3) 
When clean up procedures are complete, 
unit will be ready for cold operation.
To assure maximum compressor life, do not 
switch from “hot” to “cold” operation without 
allowing a cool down period.  Never switch from 
hot to cold operation while hot water remains in 
the pans.  Failure to observe this warning will 
greatly reduce compressor life and eventually 
cause premature compressor failure.
Switching from Cold to Hot Operation
No special procedure is required to switch from cold to hot 
operation. Be sure to fill with a minimum of 4” of water.
This unit is designed so that the compressor 
and the heating elements cannot operate at 
the same time.  Continued operation of the 
compressor in the “hot position” should not 
be considered normal.  Call for service if this 
happens.
The unit must be turned off when not in use or overnight for 
defrosting and cleaning.
Reversing And Replacing Panels
Shelleybasic laminated panels are reversible. All panels are 
replaceable. The panels sit in an upper and lower track. 
Remove first an end panel. Gain access from the back of the 
unit. Place one hand inside the unit on the panel, and one hand 
on the panel outside the unit. Push the panel out and lift the 
panel up. Remove the panel from the lower track and then the 
upper track. By removing an end panel first you will have better 
access to the front panel. Repeat the process for the front panel 
and the other end panel.
To install new or reversed panels, insert the panel into the 
upper track. Continue placing the panel into the unit and lower it 
into the lower track.