Справочник Пользователя для Master Bilt MCR-33-102PT

Скачать
Страница из 6
REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS
3
All condensing units must include a suction accumulator. Pull down time reflects time neces-
sary to lower listed quantity of food from 140°F to 40°F. All units listed contain R-404A refrigerant. 
COND. 
UNIT
MODEL*
H.P.
BTUH 
@ -10°F 
SUCTION 
TEMP.**
UNIT CONNECTION 
SIZES
DIMENSIONS
SEE 
DRAWING...
(PP. 4-5)
RECEIVER 
PUMPDOWN 
CAP. @ 90%
SHIP 
WT.
(LB/KG) MCA**
MOP**
RLA**
LRA**
LIQUID SUCTION
MCR-33-101, 200 LB. CAPACITY, 2 HOUR PULL DOWN TIME
MSLZ0101C
3
10,653
3/8
7/8
M2
11.4
200/91
20
30
11.1
77
MHLZ0121B
3
11,559
1/2
1-1/8
M2
11.4
260/118
30
45
19
105
MCLZ0111B
3
10,372
1/2
7/8
M2
11.4
330/150
24
35
14.7
86
MCLZ0111C
3
10,343
1/2
7/8
M2
11.4
330/150
19
25
10
82
MCR-33-101, 200 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME
MSLZ0151C
4
14,994
1/2
7/8
M2
11.4
230/105
32
40
15
99
BSLZ0400B
4
15,047
1/2
7/8
C
41.5
510/232
42
60
26.8
129
BSLZ0400C
4
15,047
1/2
7/8
C
41.5
510/232
32
40
15
99
BSLZ0400E
4
15,047
1/2
7/8
C
41.5
510/232
20
20
8.2
50
BCLZ0280B
3
15,529
5/8
1
1
/
8
C
41.5
505/230
32
40
15
105
BCLZ0280C
3
15,529
5/8
1
1
/
8
C
41.5
505/230
32
35
12.6
112
BCLZ0280E
3
15,529
5/8
1
1
/
8
C
41.5
505/230
20
20
6.2
56
MCR-33-101, 250 LB. CAPACITY, 2 HOUR PULL DOWN TIME
MSLZ0151C
4
14,994
1/2
7/8
M2
11.4
230/105
32
40
15
99
MCLZ0141B
3
13,799
1/2
1
3
/
8
M2
11.4
500/227
28
40
16.7
105
MCLZ0141C
3
13,903
1/2
1
1
/
8
M2
11.4
500/227
26
35
12.8
112
BSLZ0400B
4
15,047
1/2
7/8
C
41.5
510/232
42
60
26.8
129
BSLZ0400C
4
15,047
1/2
7/8
C
41.5
510/232
32
40
15
99
BSLZ0400E
4
15,047
1/2
7/8
C
41.5
510/232
20
20
8.2
49.5
BCLZ0280B
3
15,529
5/8
1
1
/
8
C
41.5
505/230
32
40
15
105
BCLZ0280C
3
15,529
5/8
1
1
/
8
C
41.5
505/230
32
35
12.6
112
BCLZ0280E
3
15,529
5/8
1
1
/
8
C
41.5
505/230
20
20
6.2
56
MCR-33-101, 250 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME
MSLZ0181C
5
18,945
1/2
1
1
/
8
M3
15.2
240/109
36
55
21.4
123
MDLZ0201C
3
19,518
1/2
1
1
/
8
M3
15.2
530/241
38
45
16.8
102
MCR-33-101, 250 LB. CAPACITY, 1.3 HOUR PULL DOWN TIME
BSLZ0600C
6
21,651
1/2
7/8
C
41.5
550/250
41
60
23.9
156
BCLZ0400C
4
21,531
5/8
1
3
/
8
C
41.5
530/230
44
60
26.3
161
BCLZ0400E
4
21,531
5/8
1
3
/
8
C
41.5
530/230
22
30
10.2
60
BSLZ0600E
6
21,651
1/2
7/8
C
41.5
550/250
21
25
9.3
70
MCR-33-101 250 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME
BCLZ0750C
7
1
/
2
37,322
7/8
1
3
/
8
D
53.4
730/332
55
80
31.5
161
BCLZ075UE
7
1
/
2
37,322
7/8
1
3
/
8
D
53.4
730/332
32
40
16.1
83
MCR-33-101 250 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME – WATER COOLED CONDENSING UNITS
SCLZ075WC
7
1
/
2
39,600
5/8
1
3
/
8
D
78.4
730/332
50
80
31.5
161
SCLZ075WE
7
1
/
2
39,600
5/8
1
3
/
8
D
78.4
750/341
32
40
16.1
83
MCR-33-102, 400 LB. CAPACITY, 2 HOUR PULL DOWN TIME
MSLZ0221C
6
23,018
1/2
1
1
/
8
M5
17
250/114
39
60
23.9
156
MDLZ0231C
4
22,958
1/2
1
1
/
8
M3
15.2
530/241
42
60
26.3
161
BCLZ040LC
4
23,171
5/8
1
3
/
8
C
41.5
530/241
45
70
26.3
161
MCR-33-102, 400 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME
MDLZ0291C
6
29,187
5/8
1
3
/
8
M5
17
560/255
47
70
28.2
161
MCR-33-102, 500 LB. CAPACITY, 2 HOUR PULL DOWN TIME
MDLZ0291C
6
29,187
5/8
1
3
/
8
M5
17
560/255
47
70
28.2
161
BSLZ0750C
7
1
/
2
26,006
1/2
7/8
C
41.5
550/250
54
80
30.9
189
BCLZ0600C
6
26,466
5/8
1
3
/
8
C
41.5
560/255
46
70
28.2
161
BCLZ0600E
2
26,466
5/8
1
3
/
8
C
41.5
560/255
26
35
13.3
80
*VOLTAGE KEY: 
“B” suffix = 208-230 or 230 volt, 60 cycle, one phase
“C” suffix = 200-230 or 208-230 volt, 60 cycle, three phase
“E" suffix = 460 volt, 60 cycle, three phase
**Based on 90°F ambient
***Electrical ratings for condensing unit only. See National  
  Electrical Code if units are combined on a single circuit.