INTRODUCTION 
 
Thank you for purchasing a Master-Bilt cabinet.  This manual contains important instructions for installing, 
using and servicing a Master-Bilt MPM/QMPM series open air case.  Read all these documents carefully 
before installing or servicing your equipment.  This manual should be left in the care of the store owner or 
manager. 
 
STORE CONDITIONS / LOCATION 
 
The Master-Bilt MPM/QMPM cases are designed to operate in the controlled environment of an air conditioned 
store.  The store temperature should be at or below 75
°F and a relative humidity of 55% or less.  At higher 
temperature or humidity conditions, the performance of these cases may be affected and the capacity 
diminished.  It is not uncommon in a newly constructed store for the temperature and humidity to be above 
design conditions.  These excessive conditions may produce sweating in the case until the store is operational 
and the ambient environment is more desirable.  
 
The Master-Bilt MPM/QMPM should not be positioned where it is directly exposed to rays of the sun or near a 
direct source of radiant heat or air flow. No HVAC return or supply air ducts may be located near case 
openings.  This will adversely affect the case air flow and will result in poor performance.  Do not open windows 
or doors that will affect the case air flow.  The maximum air velocity near the case air return is 50 FPM.  If this 
case is to be located against a wall there should be at least a  6” space between the wall and the back of the 
case. The cabinet also requires a clearance of 10” at the top.  This space will allow for the circulation of air 
behind the case.  
 
 
These cases should always be loaded properly.  This unit will operate differently when loaded or unloaded.  
Consult the section of this manual that specifies loading procedures on page 6. 
 
A P-trap is included with each case.  It is important that each case has a P-trap installed.  Check drain tubing to 
insure that it is traped and routed into the condensate pan. 
 
 
NOTICE 
 
Read this manual before installing your cabinet.  Keep the manual and refer to it before doing any 
service on the equipment.  Failure to do so could result in personal injury or damage to the cabinet. 
 
 
DANGER
 
 
Improper or faulty hook-up of electrical components of the refrigeration units can result in severe 
injury or death. 
 
All electrical wiring hook-ups must be done in accordance with all applicable local, regional or national 
standards.
 
 
NOTICE
 
 
Installation and service of the refrigeration and electrical components of the cabinet must be 
performed by a refrigeration mechanic and/or a licensed electrician.