Листовка для Master Bilt QMVM-36L

Скачать
Страница из 2
908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com
QMVM-L SERIES
QUANTUM SERIES MEDIUM TEMP LOW PROFILE 
OPEN DISPLAY MERCHANDISERS
TECHNICAL SPECIFICATIONS
1082-4/06-aq
©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.
All specifications subject to change without notice.
LISTINGS
HOOKUP
BID SPECIFICATIONS
Item no. QMVM-_______L
Provide__________(         ) Quantum Series 
Medium Temp Low Profile Open Display 
Merchandiser(s), Master-Bilt model no. 
QMVM-_______L.
Merchandiser to have standard electronic 
controller eliminating the need for a room 
thermostat, defrost termination/fan delay 
control, defrost timer and digital thermom-
Electrical hookup:  115v 
Plumbing hookup:  Requires connection 
 
to customer’s drain
eter or other temperature indicator.
Merchandiser to have two-position 
shelves adjustable in 1" increments, perfo-
rated interior back wall, independent shelf 
lighting and price tag molding. Merchan-
diser will also contain 2" foamed-in-place 
“zero ODP” urethane insulation. 
The refrigeration system is to be self-con-
tained, with front condenser air intake and 
rear air discharge and use R-134a refriger-
ant. The temperature range is 34° to 41°F (1° 
to 5°C). Merchandiser to have standard lim-
ited 4 year extended compressor warranty 
and 1 year limited parts and labor warranty. 
It is also to be UL and C-UL listed and UL 
EPH classified.
RECOMMENDED OPERATING CONDITIONS
• Merchandisers designed to hold product  
in the 34° to 41°F (1° to 5°C) range
• Designed to operate in air-conditioned 
stores where the maximum temperature is 
75°F and the maximum relative humidity 
is 55%
• Should not be installed in direct sunlight
• Should not be installed near HVAC vents, 
fans or doorways that will disrupt airflow  
and compromise the function of the air 
screen inside the case
• Bottom shelf should not be loaded such 
that the front air intake is obstructed
• Floor drain should be properly trapped
• Factory installed controls should not 
be altered, removed or replaced without 
consent of the factory
• Product must not be displayed in the cold 
air curtain 
MODEL
DIMENSIONS
(in.)
DIMENSIONS
(mm)
VOLTS
AMPS
UNIT
H.P.
NO. OF
SHELVES
STANDARD
SHELF 
SIZE 
(in inches)
CAP.
CU. 
FT.
SHIP
CU. 
FT.
SHIP
WT.
LB/KG
L
D
H
L
D
H
QMVM-36L
36
30
60
914
762 1524
115
14.8
1/2
2
14 x 31
1
/
8
11.2
67.0
490/223
QMVM-48L
48
30
60
1219 762 1524
115
14.9
3/4
2
14 x 43
1
/
8
15.4
81.0
580/264
PLAN VIEW
SIDE VIEW
ELEVATION VIEW
NEMA 5-20P