LP Gas Orifice Spud Chart for TripleTier
®
 Flame Burners
7. Replace burner plate, head and cap. 
8. Place Natural gas orifice spuds in plastic parts bag for future 
use and keep with literature package.
9. Reinstall the warming drawer. See the “Replace Oven Racks 
& Warming Drawer” section for instructions.
10. Complete installation. See “Make Gas Connection” and 
“Electronic Ignition System” sections.
Checking for proper cooktop burner flames is very important. 
The small inner cone should have a very distinct blue flame 
¼" to ½" long. The outer cone is not as distinct as the inner 
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Natural Gas Conversion
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
2. Unplug range or disconnect power
3. Remove warming drawer. See the “Remove Warming 
Drawer” section for instructions. Locate gas pressure 
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator.
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “LP” or “NAT” position. 
7. Turn over the spring retainer so the “NAT” is showing on the 
bottom. 
8. Snap the spring retainer back into the cap. 
9. Reinstall the cap onto the regulator.
To Convert Standard Surface Burners
1. Remove burner cap. 
2. Using a T20 TORX
®
 screwdriver, remove the burner base.
3. Apply masking tape to the end of a 
7 mm nut driver to help 
hold the gas orifice spud in the nut driver while changing it. 
Press nut driver down onto the gas orifice spud and remove 
by turning it counterclockwise and lifting out, set gas orifice 
spud aside. 
Burner Location
Burner Rating
Color
Size
Left front (external 
TripleTier
®
 burner)
11,800 Btu/h
Brown
1.00 mm
Left front (internal 
TripleTier
®
 burner)
  2,200 Btu/h
Orange
0.42 mm
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C
A. Gas pressure regulator
A. Access cap
B. Gasket
C. Gas pressure regulator
D. Spring retainer 
NAT position
E. Spring retainer 
LP position
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
A
A
B
C
D
E
A
B
C
D