  3.2  Burner and nozzle characteristics table 
 
 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31  28/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
Auxiliary 
1.05 
50 
30 
350 
76 
75 
Semi rapid 
1.8 
65 
33 
450 
130 
128 
Rapid 
2.3 
75 
45 
800 
166 
164 
Ultrarapid 
3.5 
94 
65 
1.6 
253 
250 
 
 
Burner 
 
Rated  
heating  
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary 
1.05 
72 
350 
Semi rapid 
1.8 
97 
450 
Rapid 
2.3 
103 
800 
Ultrarapid 
3.5 
133 
1500 
 
 
 
  3.3 
Arrangement of burners on cooking hob 
  
 
BURNERS 
 
1 Auxiliary 
2 Semi 
rapid 
3 Rapid 
4 Ultrarapid 
22