Section 1
1.
GETTING STARTED
1.1
INTRODUCTION
Congratulations on your purchase of the Siemens SITRANS FUS1010 NEMA Permanent Flowmeter.
Intended for dedicated applications, this versatile transit-time flowmeter is easy to set up and operate.
The Model FUS1010 flowmeter represents the state-of-the-art in computerized instrumentation. We
are confident that in a very short time, you will appreciate its unrivaled performance and features;
especially Siemens’s ground breaking enhanced transit-time Digitally Coded MultiPuls technology and
the on-line automatic and interactive site setup facility. This manual covers FUS1010 Single Channel,
Dual Channel/Dual Path and 4-Channel/4-Path flowmeter types in NEMA-4 or NEMA-7 enclosures.
Only the Model 1010FTN and 1010AN flowmeters are equipped to utilize the flow tubes shown in
Section 6.
This section shows how to install the System FUS1010 flowmeter with a minimal amount of effort. It
will show how to use the Installation Menu to set up the system for transit-time, Reflexor and Flow Tube
Clamp-on operation. It also shows the basic connections to and from the flowmeter. For additional
information on connections, see the drawings at the end of  manual.
1.2
IMPORTANT SAFETY CONSIDERATIONS
The FUS1010 NEMA Permanent meter operates from either an external AC or DC power source.
Please observe all the electrical safety codes, etc., that apply to your application. We recommend that
only experienced personnel with knowledge of local electrical codes and safety operating procedures
perform the installation and wiring. It is solely the user’s responsibility to operate this equipment safely.
Siemens cannot accept responsibility for any damage that may occur due to failure to observe any
local safety rules.
If this equipment is used for a hazardous application (high line pressure, hostile liquid characteristics,
perilous atmosphere, etc.), the end-user must ensure that only properly trained personnel are involved
in its installation and operation.
Please do not let the size of the Installation Menu intimidate you. Almost all menu cells already contain
default parameters. To begin operation, you only need to access the menu cells that control a required
parameter, such as the pipe outer diameter. You will see that by accepting most defaults, you can set
up the meter in about five minutes.
1.3
FLOWMETER INSTALLATION STEPS
Typical steps to complete the installation procedure.
z
Collect the site data (pipe and liquid data, part numbers, etc.)
z
Choose a mounting location for the flow computer and transducers.
z
Mount the flow computer at the selected location.
z
Prepare pipe for transducer mounting.
z
Access the Installation Menu and create a site (see paragraph 1.7.3).
z
Enter pipe parameters (see paragraph 2.2).
z
Invoke transducer install procedure (see paragraph 2.4).
z
Mount transducers on pipe and connect to flow computer (see Section 3).
z
Complete transducer install menu operation (see paragraph 2.4).