BASIC HARDWARE CONNECTIONS
CM9700-CC1 CONNECTION
Use the 16-pin terminal block for the RS-422 serial connection (Pelco P protocol) between the CM9700MDD-EVS and the CM9700-CC1.
The terminal block has tension clamps instead of screw terminals. Use a small screwdriver to open the clamp for a particular lead. Figure 11 shows 
how to wire the terminal block and connect it to the CM9700MDD-EVS.
NOTE: The terminal block can be attached to the CM9700MDD-EVS only in the proper position, as shown in Figure 11.
Figure 11.  Wiring the CM9700MDD-EVS Terminal Block
1. Use a Cat5e (or better) cable (user-supplied) with an RJ-45 connector at one end and with the individual wires exposed at the other end to 
connect the CM9700MDD-EVS to the CM9700-CC1. 
2. Connect the cable’s individual wires to the terminal block on the rear panel of the CM9700MDD-EVS. An arrow on the rear panel identifies 
pin 1; on the terminal block, pin 1 is the leftmost lead on the top row and pin 9 is the leftmost lead on the bottom row (refer to Figure 11).
Figure 12 illustrates the cable connections on each end.
3. Insert the cable’s RJ-45 connector into any available RS-422 COM port on the CM9700-CC1. 
NOTE: When connecting peripheral equipment to the CM9700-CC1 serial communication ports, shielded cabling is required to comply with CE 
emissions guidelines.
Table A identifies the RS-422 pin assignments on the CM9700MDD-EVS and the CM9700-CC1. Note that the alarm and relay inputs on the 
CM9700MDD-EVS are reserved for future use, and are not included in this table. 
Table A.  RS-422 Pin Assignments
CM9700-CC1
CM9700MDD-EVS
Pin
Lead
Pin
Label
Lead
1
RS-422 Data TX+
1
TX-
RS-422 Data TX-
2
RS-422 Data TX-
2
RX-
RS-422 Data RX-
7
RS-422 Data RX-
9
TX+
RS-422 Data TX+
8
RS-422 Data RX+
10
RX+
RS-422 Data RX+
PIN 1
PIN 1