Справочник Пользователя для Siemens RL-854
RL-854 Radio Control Unit
Type I, Style A
Type I, Style A
Operation
2001 Siemens Airfield Solutions, Incorporated
96A0027L
Page 23
All rights reserved
Issued 5/01
The RL-854PR contains three 2-pole power relays that are rated for 25 amps
(resistance) per pole. The auxiliary terminal strip TB1 handles up to AWG
10 wire. Wire the RL-854PR as follows:
(resistance) per pole. The auxiliary terminal strip TB1 handles up to AWG
10 wire. Wire the RL-854PR as follows:
1. Terminal 1 and Terminal 2 - closes when 7-pulse relay is powered.
2. Terminal 3 and Terminal 4 - closes when 7-pulse relay is powered.
3. Terminal 5 and Terminal 6 - closes when 5-pulse relay is powered.
4. Terminal 7 and Terminal 8 - closes when 5-pulse relay is powered.
5. Terminal 9 and Terminal 10 - closes when 3-pulse relay is powered.
6. Terminal 11 and Terminal 12 - closes when 3-pulse relay is powered.
7. Terminal 13 - line (120 Vac), black wire.
8. Terminal 14 - neutral (120 Vac return), white wire.
2. Terminal 3 and Terminal 4 - closes when 7-pulse relay is powered.
3. Terminal 5 and Terminal 6 - closes when 5-pulse relay is powered.
4. Terminal 7 and Terminal 8 - closes when 5-pulse relay is powered.
5. Terminal 9 and Terminal 10 - closes when 3-pulse relay is powered.
6. Terminal 11 and Terminal 12 - closes when 3-pulse relay is powered.
7. Terminal 13 - line (120 Vac), black wire.
8. Terminal 14 - neutral (120 Vac return), white wire.
9. Terminal 15 – earth ground, green wire.
This section describes operations of the RL-854 Radio Control unit.
The RL-854 is shipped for individual relay operation. Under individual
relay operation:
relay operation:
•
3 pulses closes the 3-pulse relay
•
5 pulses closes the 5-pulse relay and opens the 3-pulse relay
•
7 pulses closes the 7-pulse relay and opens the 5-pulse relay
The relay operation can be changed for incremental relay operation, which
is as follows:
is as follows:
•
3 pulses closes the 3-pulse relay
•
5 pulses closes the 5-pulse and 3-pulse relays
•
7 pulses closes the 7-pulse and 5-pulse relays
Installing RL-854PR Radio
Controller
Controller
(contd.)
4. Operation
Incremental Relay Option