5. PARAMETERS 
5 -  6 
 
5.4 Extension setting parameters (No.PC
5.4.1 Parameter list 
POINT  
For details of the parameters in which columns MR-J3- B is written, refer to the 
MR-J3- B Servo Amplifier Instruction Manual section 5.3. 
The parameter whose symbol preceded by * can be validated with the following 
conditions. 
* : Turn off the power and then on again, or reset the controller after setting the 
parameter. 
Never change the parameters for the manufacturer setting. 
 
 
No. Symbol 
Name 
Initial 
value Unit  Reference 
PC01 
*ERZ  Error excessive alarm level 
rev 
MR-J3- B 
PC02 
MBR 
Electromagnetic brake sequence output 
ms 
 
PC03 
*ENRS  Encoder output pulses selection 
0000h 
 
 
PC04 
0000h 
PC05 
0000h 
PC06 
 
For manufacturer setting 
0000h 
 
 
PC07 ZSP Zero 
speed 
50 
r/min MR-J3- B 
PC08 
 
For manufacturer setting 
 
 
PC09 
MOD1  Analog monitor 1 output 
0000h 
 
PC10 
MOD2  Analog monitor 2 output 
0001h 
 
PC11 
MO1 
Analog monitor 1 offset 
mV 
PC12 
MO2 
Analog monitor 2 offset 
mV 
MR-J3- B 
PC13 
For manufacturer setting 
PC14  
PC15  
PC16 
 
 
0000h 
 
 
PC17 
 
For manufacturer setting (Note) 
0000h 
 
 
PC18 
For manufacturer setting 
0000h 
PC19 
 
 
0000h 
 
 
PC20 
*COP7  Function selection C-7 
0000h 
 
PC21 *BPS Alarm 
history clear 
0000h 
 
MR-J3- B 
PC22 
For manufacturer setting 
0000h 
PC23  
0000h 
PC24  
0000h 
PC25  
0000h 
PC26  
0100h 
PC27  
0000h 
PC28  
0000h 
PC29  
0000h 
PC30  
0000h 
PC31  
0000h 
PC32 
 
 
0000h 
 
 
Note. This parameter is "Function selection C-4" for the MR-J3- B servo amplifier, however the parameter is not available for the MR-J3-
B-RJ080W servo amplifier. If the setting is changed, a parameter error (37) occurs.