Справочник Пользователя для Mitsubishi Electronics FR-A701

Скачать
Страница из 259
196
APPENDICES
Appendix 1 Main differences and compatibilities with the FR-A700 series
Item
FR-A700
FR-A701
Model configuration
200V class ......0.4K to 90K
400V class ......0.4K to 500K
200V class ..... 5.5K to 55K
400V class ..... 5.5K to 55K
Regenerative braking 
torque
5.5/7.5K...........100%torque 2%ED
11K to 55K.....20%torque continuous
100% torque/continuous 
150% torque 60s
Built-in EMC filter
With
Without
Changed/cleared 
functions
Pr. 30 Regenerative function selection, Pr. 70 Special 
regenerative brake duty
Deleted
Pr. 872 Input phase loss protection selection
Initial value "0" (without input phase protection)
The initial value is changed to "1" (with input phase 
failure protection)
Protective functions
E.BE
Deleted
E.4, E.10, E.8, E.15 added
Stand-alone option
· AC reactor (FR-HAL)
· DC reactor (FR-HEL)
· High-duty brake resistor (FR-ABR)
· Power regeneration common converter (FR-CV)
· High power factor converter (FR-HC)
· Power regeneration converter (FR-RC)
Not available
(AC reactor (FR-HAL) is built-in)
* Note that an AC reactor (FR-HAL) should be used only 
when a thyristor load exists in the same power supply 
system and protective function E.4 and E.10 activate.
Outline dimension
Installation size
Not compatible