Справочник Пользователя для Mitsubishi Electronics FR-A701

Скачать
Страница из 259
61
Before operation
4.3.6
Change acceleration and deceleration time (Pr. 7, Pr. 8)
* Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and setting increments is
"0.1s".
Set in Pr. 7 Acceleration time a larger value for a slower speed increase and a smaller value for a faster speed increase.
Set in Pr. 8 Deceleration time a larger value for a slower speed decrease and a smaller value for a faster speed decrease.
Parameter 
Number
Name
Initial Value
Setting Range
Description
7
Acceleration time
7.5K or lower
5s
0 to 3600/360s 
*
Set the motor acceleration time.
11K or higher
15s
8
Deceleration time
7.5K or lower
5s
0 to 3600/360s 
*
Set the motor deceleration time.
11K or higher
15
Changing example
Change  the  Pr. 7 Acceleration time setting from "5s" to
"10s".
Running 
frequency
Acceleration 
time
Deceleration 
time
Time
Pr.20
Pr.7
Pr.8
Output 
frequency 
(Hz)
Pr.110
Pr.111
Pr.44
Pr.45
(60Hz)
1.
Screen at power-ON
     The monitor display appears.
Display
Operation
3.
Press        to choose the parameter 
     setting mode.
4.
Pr. 7) appears.
Flicker ··· Parameter setting complete!!
7.
Press        to set.
PU indicator is lit.
2.
Press         to choose the PU operation
     mode.
· Press        to show the setting again.
· Press        twice to show the next parameter.
· By turning        , you can read another parameter.
The initial value
 differs according
 to the capacity.
5.
Press        to read the currently set value.
     "      "(initial value) appears.
6.
Turn        to change it to the set 
     value "        ".
The parameter 
number read
 previously appears.