Basic configuration and connection 
of peripheral devices
1.1.2
Selection of peripheral devices
Check the capacities of the motor applicable to the inverter you purchased. Refer to the list below and prepare
appropriate peripheral devices.
200V class
400V class
*1. Select the NFB type according to the power supply capacity.
Caution
• Do not fit capacitive equipm ent such as power factor correction capacitor, radio noise filter (FR-BIF
option) or surge suppressor to the output side of the inverter. This will cause the inverter to trip or power
factor correction capacitor and surge suppressor to be dam aged. If any of the above devices are con-
nected, im m ediately rem ove them . If the FR-BIF radio noise filter is connected, switching pow er off during
m otor operation m ay result in "E.UVT". In this case, connect the radio noise filter on the prim ary side of
the m agnetic contactor.
• Electromagnetic wave interference
The input/output (main circuit) of the inverter includes harmonic components, which may interfere with
the communication devices (such as AM radios) used near the inverter. In this case, install the FR-BIF
optional radio noise filter (for use in the input side only) or FR-BSF01 or FR-BLF line noise filter to mini-
mize interference.
Motor
Output 
(kW)
Applicable
Inverter
Type
No-fuse Breaker
(NFB
*1
or Earth Leakage Cir-
cuit Breaker (ELB
)
Power Factor 
Im proving AC 
Reactor
Power Factor 
Im proving DC 
Reactor
Magnetic 
Contactor 
(MC)
Standard
With power factor 
im proving reactor
1.5 
FR-V520-1.5K
30AF 15A
30AF 15A
FR-BAL-1.5K
FR-BEL-1.5K
S-N10
2.2 
FR-V520-2.2K
30AF 20A
30AF 15A
FR-BAL-2.2K
FR-BEL-2.2K
S-N11, N12
3.7 
FR-V520-3.7K
30AF 30A
30AF 30A
FR-BAL-3.7K
FR-BEL-3.7K
S-N20
5.5 
FR-V520-5.5K
50AF 50A
50AF 40A
FR-BAL-5.5K
FR-BEL-5.5K
S-N25
7.5 FR-V520-7.5K
100AF 
60A
50AF 
50A
FR-BAL-7.5K
FR-BEL-7.5K
S-N35
11 
FR-V520-11K
100AF 75A
100AF 75A
FR-BAL-11K
FR-BEL-11K
S-N50
15 
FR-V520-15K
225AF 125A
100AF 100A
FR-BAL-15K
FR-BEL-15K
S-N65
18.5 
FR-V520-18.5K
225AF 150A
225AF 125A
FR-BAL-22K
FR-BEL-18.5K
S-N80
22 
FR-V520-22K
225AF 175A
225AF 150A
FR-BAL-22K
FR-BEL-22K
S-N95
30 
FR-V520-30K
225AF 225A
225AF 175A
FR-BAL-30K
FR-BEL-30K
S-N125
37 
FR-V520-37K
400AF 250A
225AF 225A
FR-BAL-37K
FR-BEL-37K
S-N150
45 
FR-V520-45K
400AF 300A
400AF 300A
FR-BAL-45K
FR-BEL-45K
S-N180
55 
FR-V520-55K
400AF 400A
400AF 350A
FR-BAL-55K
FR-BEL-55K
S-N220
Motor 
Output 
(kW)
Applicable
Inverter
Type
No-fuse Breaker
(NFB
*1
or Earth Leakage Cir-
cuit Breaker (ELB
)
Power Factor 
Im proving AC 
Reactor
Power Factor 
Im proving DC 
Reactor
Magnetic 
Contactor 
(MC)
Standard
W ith power factor 
im proving reactor
1.5 
FR-V540-1.5K
30AF 10A
30AF 10A
FR-BAL-H1.5K
FR-BEL-H1.5K
S-N10
2.2 
FR-V540-2.2K
30AF 15A
30AF 10A
FR-BAL-H2.2K
FR-BEL-H2.2K
S-N11, N12
3.7 
FR-V540-3.7K
30AF 20A
30AF 15A
FR-BAL-H3.7K
FR-BEL-H3.7K
S-N20
5.5 
FR-V540-5.5K
30AF 30A
30AF 20A
FR-BAL-H5.5K
FR-BEL-H5.5K
S-N20
7.5 
FR-V540-7.5K
30AF 30A
30AF 30A
FR-BAL-H7.5K
FR-BEL-H7.5K
S-N20
11 
FR-V540-11K
50AF 50A
50AF 40A
FR-BAL-H11K
FR-BEL-H11K
S-N20
15 FR-V540-15K
100AF 
60A
50AF 
50A
FR-BAL-H15K
FR-BEL-H15K
S-N25
18.5 FR-V540-18.5K
100AF 
75A
100AF 
60A
FR-BAL-H22K
FR-BEL-H18.5K
S-N35
22 FR-V540-22K
100AF 
100A
100AF 
75A
FR-BAL-H22K
FR-BEL-H22K
S-N50
30 FR-V540-30K
225AF 
125A
100AF 
100A
FR-BAL-H30K
FR-BEL-H30K
S-N65
37 FR-V540-37K
225AF 
150A
225AF 
125A
FR-BAL-H37K
FR-BEL-H37K
S-N80
45 FR-V540-45K
225AF 
175A
225AF 
150A
FR-BAL-H45K
FR-BEL-H45K
S-N80
55 FR-V540-55K
225AF 
200A
225AF 
175A
FR-BAL-H55K
FR-BEL-H55K
S-N125