80
ERRORS AND PRO
T
ECTIVE 
FU
NCTIO
N
S
6
Correspondences between digital and
actual characters
6.2 Correspondences between digital and actual characters
There are the following correspondences between the actual alphanumeric characters and the digital characters
displayed on the operation panel.
6.3 Resetting the inverter
The inverter can be reset by performing any of the following operations. Note that the electronic thermal relay's
internal heat integrating value and the number of retries are cleared (erased) by resetting the inverter.
Operation 1: Using the operation panel, press 
 to reset the inverter.
(Enabled only w hen the inverter protective function (m ajor fault) is activated. (R efer to page 70 for m ajor
faults.))
Operation 2: Switch power off once, then switch it on again.
Operation 3: Turn on the reset signal (RES) for more than 0.1 second.
Actual
Digital
0
1
2
3
4
5
6
7
8
9
Actual
Digital
A
B
C
E
F
G
H
I
J
L
D
Actual
Digital
M
N
O
o
P
T
U
V
r
S
STOP
RESET