Справочник Пользователя для Mitsubishi Electronics FR-V540-1.5K to 55K

Скачать
Страница из 232
112
Operation selection function 2 (Pr. 65 to Pr. 79)
3.11.3 PWM carrier frequency selection (Pr. 72, Pr. 240
)
<Setting>
By parameter setting, you can set whether to exercise the Soft-PWM control that changes the motor tone or 
select with or without long wiring mode.
• Soft-PWM control is a control method that changes the motor noise from a metallic tone into an unoffending 
complex tone.
• Surge voltage is suppressed regardless of wiring length in the long wiring mode. (When operating the 400V 
motor with wiring length of 40m or longer, select long wiring mode.)
Parameter
Name
Factory Setting Setting Range
Remarks
72
PWM frequency 
selection
1
1 to 6
Simple mode
240
Soft-PWM setting
10
0, 1, 10, 11
Extended mode
Pr. 72
Setting
Description
1
2.25kHz
2
4.5kHz
3
6.75kHz
4
9kHz
5
11.25kHz
6
13.5kHz
CAUTION
1. An increased PWM carrier frequency will decrease the motor sound but increase noise and leakage 
currents. Therefore, perform the reduction techniques. (Refer to page 12.)
2. Since Pr. 240 is factory-set to "10", PWM carrier frequency is 2.25 kHz constant even if "2" or larger 
value is set in Pr. 72. Set "0 or 1" in Pr. 240 to decrease the motor noise.
Pr. 240
Setting
Description
Soft-PWM
long wiring mode
Remarks
0
Invalid
Invalid
———
1
Valid
(when Pr. 72 = "1 or 2")
Invalid
10
Invalid
Valid
Carrier frequency is 2.25kHz.
 
(The Pr.72 "PWM frequency selection" setting is 
made invalid.)
11
Valid
Valid
CAUTION
1. When long wiring mode is made valid, torque reduces about 5% in the constant power range.
2. The output voltage at rated frequency decreases by about 1.5V maximum (200V class)/about 3.0V 
maximum (400V class) during V/F control.
3. Use an insulation-enhanced motor for the 400V class. Refer to page 22 for inverter driving of the 400V 
class motor.
speed
torque
position