3.41.2 Biases and gains of speed setting terminals 
 
(speed setting terminal 2, torque command terminal 3, multi function terminal 1)
 
(Pr. 902 to Pr. 905, Pr. 917 to Pr. 920
)
*1 For calibration of forward/reverse rotation limit, PID control deviation and measured value.
*2 Factory settings may differ because of calibration parameters.
Adjust the biases and gains of the speed setting terminal 2, torque command terminal 3 and multi-function 
terminal 1.
 
The "bias" and "gain" functions are designed to adjust the relationship between the 0 to 10V input signal, 
which is externally input for the setting of output speed, torque or magnetic flux.
Parameter
Name
Factory Setting (*2)
Setting Range
Remarks
902
Speed setting terminal 2 bias
0V
0r/min
0 to 10V
0 to 3600r/min
Extended mode
903
Speed setting terminal 2 gain
10V
1500r/min
0 to 10V
0 to 3600r/min
904
Torque command terminal 3 
bias
0V
0%
0 to 10V
0 to 400%
905
Torque command terminal 3 
gain
10V
150%
0 to 10V
0 to 400%
917
Terminal 1 bias (speed *1)
0V
0r/min
0 to 10V
0 to 3600r/min
918
Terminal 1 gain (speed *1)
10V
1500r/min
0 to 10V
0 to 3600r/min
919
Terminal 1 bias 
 
(torque/magnetic flux)
0V
0%
0 to 10V
0 to 400%
920
Terminal 1 gain 
 
(torque/magnetic flux)
10V
150%
0 to 10V
0 to 400%
Parameter
Calibration 
Terminal
Speed Command/Speed Limit
(Pr. 807, Pr. 868, Pr. 73)
Forward/
Reverse 
Rotation 
Speed 
Limit
Torque
Magnetic 
Flux
PID Control
(Pr. 128 to Pr. 134)
Speed
(main 
speed+
auxiliary)
Compensation 
input
Override
Magnetic 
flux 
command
Torque limit 
(Pr. 810)
Torque 
command
(Pr. 804)
Torque 
bias
(Pr. 840)
Magnetic 
command
Deviation Set point
Measured 
value
902
terminal 2
 
(+terminal 
1)
 
(terminal 
1)
903
904
terminal 3
 
only
905
917
terminal 1
 
only
 
(Pr. 868)
918
919
 
(regenerative 
torque limit
 
(Pr. 868))
 
(Pr. 868)
920
CAUTION
Torque command bias and gain can not be set by applying an external negative setting signal to the 
torque command terminal 3 or 1.
speed
torque position
Pr. 902
Pr. 903
0
Setting signal
10V
Factory setting
Gain
Bias
Ou
tp
ut
 spee
(r
/min
)
(1500r/min)
Pr. 905
Pr. 904
Setting signal
10V
-10V
(150%)
Inclination is as set in 
Pr. 904 (Pr. 917, Pr. 919) 
and Pr. 905 (Pr. 918, Pr. 920).
Bias
Pr. 917
Pr. 918
Outp
ut
 sp
ee
(r
/m
in
)
T
or
q
ue 
(%
)
Gain
Pr. 919
Pr. 920
(1500r/min)