204
Outline dimension drawings
4.3.4
Dedicated encoder cable outline dimension drawings
(FR-V5CBL)
(FR-VCBL‚FR-JCBL)
(1) Cable selection specifications
If connection cables are not available, make cables according to the table above.
For the pin arrangement for the FR-VCBL/FR-JCBL, refer to page 39.
<Outline drawing>
(Unit: mm)
<Outline drawing>
(Unit: mm)
Wiring Distance
Dedicated Encoder 
Cable for Options
Cable Specification
Wiring 0.2mm
2
 Cables
Using larger gauge cable
5m or less
FR-V5CBL5
2 parallels or more
0.4mm
2
 or more
10m or less
FR-V5CBL15
2 parallels or more
15m or less
4 parallels or more
0.75mm
2
 or more
20m or less
FR-V5CBL30
4 parallels or more
30m or less
6 parallels or more
1.25mm
2
 or more
50m or less
Available on request, 
please consult us.
6 parallels or more
100m or less
F-DPEVSB 12P   0.2mm
2
L
Earth (Ground)
wire
MS3057-12A
MS3106B20-29S
60
11
Type
Length L
(m)
FR-V5CBL5
5
FR-V5CBL15
15
FR-V5CBL30
30
F-DPEVSB 12P   0.2mm
2
L
Earth (Ground)
wire
MS3057-12A
MS3106B20-29S
60
About 140
11
For the FR-VCBL/FR-JCBL, change the 
crimping terminal size from M3 to M3.5.
Type
Length L
(m)
Type
Length L
(m)
FR-VCBL5
5
FR-JCBL5
5
FR-VCBL15
15
FR-JCBL15
15
FR-VCBL30
30
FR-JCBL30
30