73
At-a-glance guide to functions
P
A
RAMETERS
3
3.2 At-a-glance guide to functions
{
....Usable function,  
× ..... Unusable function
Cat
e
go
ry
Vector with encoder
Speed
Torque
Position
SF-V5RU
"Motor with encoder (standard, 
constant torque)"
*: This function can be usable under 
position control by parameter 
setting.
Pr. number
Terminal
Cont
rol
Speed limit
Pr. 807 to Pr. 809, Pr. 873,  Pr. 902, 
Pr. 903, Pr. 917, Pr. 918
Terminal 2 (1), 
multi-speed
×
{
×
Torque limit
Pr. 22, Pr. 803, Pr. 810 to Pr. 817, 
 
Pr. 904, Pr. 905, Pr. 919, Pr. 920
Terminal 3 (1)
{
×
{
Offline auto tuning
Pr. 9, Pr. 71, Pr. 80 to Pr. 84, 
 
Pr. 90 to Pr. 94, Pr. 96, Pr. 859
{
{
×
Online auto tuning (start time) Pr. 95 = 1
Pr. 95
{
{
×
Online auto tuning
(adaptive magnetic flux observer) Pr. 95 = 2
Pr. 95
{
{
{
Easy gain tuning
Pr. 818, Pr. 819
{
×
{
Gain adjustment
Pr. 820 to Pr. 827, Pr. 830 to Pr. 837
{
{
{
Machine analyzer (notch filter)
Pr. 862, Pr. 863
{
×
{
0 speed control
Pr. 802
{
×
{
Servo lock
Pr. 802
{
×
{
Variable excitation
Pr. 854
{
{
{
Speed feed-forward, model adaptive speed control
Pr. 877 to Pr. 881, Pr. 820, 
 
Pr. 821, Pr. 828
{
×
{
P/PI switchover
Pr. 180 to Pr. 183, Pr. 187
X44 signal
{
{
{
Speed feedback filter
Pr. 823, Pr. 833
{
{
{
B
a
sic f
unct
ions
Extended function display
Pr. 160
{
{
{
Maximum speed
Pr. 1
{
{
{
Minimum speed
Pr. 2
{
{
×
Acceleration time
Pr. 7, Pr. 8, Pr. 20, Pr. 21, 
 
Pr. 44, Pr. 45, Pr. 110, Pr. 111
{
{
×
*
Acceleration/deceleration pattern
Pr. 29, Pr. 140 to Pr. 143,
 
Pr. 380 to Pr. 383
{
{
×
Jog operation mode
Pr. 15, Pr. 16
{
{
×
PWM frequency selection
Pr. 72, Pr. 240
{
{
{
Operation mode (PU/external/combined)
Pr. 79
{
{
×
Switchover mode
Pr. 79
{
{
×
PU operation interlock mode
Pr. 79, Pr. 180 to Pr. 183, Pr. 187
X12
{
{
{
Operation mode external signal switchover mode
Pr. 79, Pr. 180 to Pr. 183, Pr. 187
X16
{
{
{
Start command (2-wire, 3-wire)
Pr. 180 to Pr. 183, Pr. 187
STOP
{
{
{
Parameter write disable selection
Pr. 77
{
{
{
Ap
plicat
ion fu
nctio
ns
Starting speed
Pr. 13
{
{
×
DC injection brake
Pr. 10, Pr. 11, Pr. 12
{
{
×
Second, third functions
Pr. 180 to Pr. 183, Pr. 187
RT, X9
{
{
{
Multi-speed setting
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 28, 
 
Pr. 232 to Pr. 239
{
{
×
*
Remote setting
Pr. 59
{
{
×
Speed jump
Pr. 31 to Pr. 36
{
{
×
PID control
Pr. 128 to Pr. 134, Pr. 180 to Pr. 183, 
Pr. 187
X14
{
×
×
Stop selection
Pr. 250
{
{
×
Power failure stop
Pr. 261 to Pr. 266
{
{
×
PU stop
Pr. 75
{
{
{
Reset selection
Pr. 75
{
{
{
Forward/reverse rotation prevention
Pr. 78
{
{
{
Automatic restart after instantaneous power failure
Pr. 57, Pr. 58
{
{
×
Cooling fan on/off control
Pr. 244
{
{
{
Retry function
Pr. 65, Pr. 67 to Pr. 69
{
{
×
Inverter RS485 communication
Pr. 117 to Pr. 124
{
{
{
Droop control
Pr. 286 to Pr. 288
{
×
×
Control
Applicable 
Motor
Function