Pr.
Name
Setting Range
Initial
Value
Value
0 Torque boost
0 to 30%
6/4/3/2%
1 Maximum frequency
0 to 120Hz
120Hz
2 Minimum frequency
0 to 120Hz
0Hz
3 Base frequency
0 to 400Hz
60Hz
4 Multi-speed setting (high
speed)
0 to 400Hz
60Hz
5
Multi-speed setting (middle
speed)
speed)
0 to 400Hz
30Hz
6 Multi-speed setting (low
speed)
0 to 400Hz
10Hz
7 Acceleration time
0 to 3600s
5/10/15s
8 Deceleration time
0 to 3600s
5/10/15s
9 Electronic thermal O/L relay
0 to 500A
Rated
inverter
current
10
DC injection brake operation
frequency
frequency
0 to 120Hz
3Hz
11
DC injection brake operation
time
time
0 to 10s
0.5s
12
DC injection brake operation
voltage
voltage
0 to 30%
6/4/2%
13
Starting frequency
0 to 60Hz
0.5Hz
14
Load pattern selection
0 to 3
0
15
Jog frequency
0 to 400Hz
5Hz
16
Jog acceleration/deceleration
time
time
0 to 3600s
0.5s
17
MRS input selection
0, 2, 4
0
18
High speed maximum
frequency
frequency
120 to 400Hz
120Hz
19
Base frequency voltage
0 to 1000V,
8888, 9999
8888, 9999
9999
20
Acceleration/deceleration
reference frequency
reference frequency
1 to 400Hz
60Hz
22
Stall prevention operation level 0 to 200%
150%
23
Stall prevention operation level
compensation factor at double
speed
compensation factor at double
speed
0 to 200%, 9999
9999
24
Multi-speed setting (speed 4)
0 to 400Hz, 9999
9999
25
Multi-speed setting (speed 5)
0 to 400Hz, 9999
9999
26
Multi-speed setting (speed 6)
0 to 400Hz, 9999
9999
27
Multi-speed setting (speed 7)
0 to 400Hz, 9999
9999
29
Acceleration/deceleration
pattern selection
pattern selection
0, 1, 2
0
30
Regenerative function
selection
selection
0, 1, 2
0
31
Frequency jump 1A
0 to 400Hz, 9999
9999
32
Frequency jump 1B
0 to 400Hz, 9999
9999
33
Frequency jump 2A
0 to 400Hz, 9999
9999
34
Frequency jump 2B
0 to 400Hz, 9999
9999
35
Frequency jump 3A
0 to 400Hz, 9999
9999
36
Frequency jump 3B
0 to 400Hz, 9999
9999
37
Speed display
0,
0.01 to 9998
0.01 to 9998
0
40
RUN key rotation direction
selection
selection
0, 1
0
41
Up-to-frequency sensitivity
0 to 100%
10%
42
Output frequency detection
0 to 400Hz
6Hz
43
Output frequency detection for
reverse rotation
reverse rotation
0 to 400Hz, 9999
9999
44
Second acceleration/
deceleration time
deceleration time
0 to 3600s
5/10/15s
45
Second deceleration time
0 to 3600s, 9999
9999
46
Second torque boost
0 to 30%, 9999
9999
47
Second V/F (base frequency)
0 to 400Hz, 9999
9999
48
Second stall prevention
operation current
operation current
0 to 200%, 9999
9999
51
Second electronic thermal O/L
relay
relay
0 to 500A, 9999
9999
52
DU/PU main display data
selection
selection
0, 5, 8 to 12, 14,
20, 23 to 25,
52 to 55, 61, 62,
64, 100
20, 23 to 25,
52 to 55, 61, 62,
64, 100
0
54
FM terminal function selection
1 to 3, 5, 8 to 12,
14, 21, 24, 52,
53, 61, 62
14, 21, 24, 52,
53, 61, 62
1
55
Frequency monitoring
reference
reference
0 to 400Hz
60Hz
56
Current monitoring reference
0 to 500A
Rated
inverter
current
57
Restart coasting time
0, 0.1 to 5s,
9999
9999
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function selection
0, 1, 2, 3
0
60
Energy saving control
selection
selection
0, 9
0
65
Retry selection
0 to 5
0
66
Stall prevention operation
reduction starting frequency
reduction starting frequency
0 to 400Hz
60Hz
67
Number of retries at fault
occurrence
occurrence
0 to 10,
101 to 110
101 to 110
0
68
Retry waiting time
0.1 to 600s
1s
69
Retry count display erase
0
0
70
Special regenerative brake
duty
duty
0 to 30%
0%
71
Applied motor
0, 1, 3, 13, 23,
40, 43, 50, 53
40, 43, 50, 53
0
72
PWM frequency selection
0 to 15
1
73
Analog input selection
0, 1, 10, 11
1
74
Input filter time constant
0 to 8
1
75
Reset selection/disconnected
PU detection/PU stop
selection
PU detection/PU stop
selection
0 to 3,
14 to 17
14 to 17
14
77
Parameter write selection
0, 1, 2
0
78
Reverse rotation prevention
selection
selection
0, 1, 2
0
79 Operation mode selection
0, 1, 2, 3, 4, 6, 7
0
80
Motor capacity
0.1 to 15kW,
9999
9999
9999
82
Motor excitation current
0 to 500A, 9999
9999
83
Rated motor voltage
0 to 1000V
200V/
400V
∗4
Pr.
Name
Setting Range
Initial
Value
Value