APPENDIX 6  OUTLINE AND INSTALLATION DIMENSIONS FOR GROUNDING PLATE AND   
CLAMP FITTING 
 
 
I - 84 
APPENDIX 6    OUTLINE AND INSTALLATION DIMENSIONS FOR 
GROUNDING PLATE AND CLAMP FITTING 
 
The shield wire generally only needs to be grounded 
to the connector's case frame. However, the effect 
can be improved by directly grounding to the 
grounding plate as shown on the right. 
Install the grounding plate near each unit. Peel off 
part of the cable sheath as shown on the right to 
expose the shield sheath. Press that section against 
the grounding plate with the clamp fitting. Note that if 
the cable is thin, several can be clamped together. 
Install the grounding plate directly onto the cabinet or 
connect a grounding wire so that sufficient frame 
grounding is achieved. 
If the AERSBAN- 
†  SET, containing the grounding 
plate and clamp fitting, is required, please contact 
Mitsubishi. 
 
 
Clamp section drawing 
Clamp fitting 
(Fitting A,B)
 
Grounding
Plate
Cable
Shield sheath
 
40
 
 
 
 
 
Outline drawing 
 
Grounding plate 
2-
φ
5 hole 
Installation hole 
17.5 
M4 screw 
Note 1) 
6
22 
35 
10
MAX  L
Clamp fitting 
35 
24 
-0
.2
 
B
±0.3 
11
30 
24 
+0
.3
 
 
 
Note 1)    Screw hole for wiring to cabinet's grounding plate 
Note 2)    The grounding plate thickness is 1.6mm 
 
 
A B C Enclosed 
fittings   
 
AERSBAN-DSET 
100 
86 
30 
Two clamp fittings A 
 
Clamp fitting A 
70 
AERSBAN-ESET 70  56 
- 
One clamp fitting B 
 
Clamp fitting B 
45