APPENDIX 7    CABLE MANUFACTURING DRAWINGS 
Appendix 7.6    F340 Cable Manufacturing Drawing 
 
 
I - 91 
Appendix 7.6  F340 Cable Manufacturing Drawing 
 
Application : External skip signal input (4 points) 
 
List of parts used 
 
F340 
 
Note (2) 
1 2
5
Cotrol  
unit side 
Skip signal input
SK
IP
 
F340 
Assembly drawing 
No.
Part name/type 
Maker 
Q'ty
Connector 
CDE-9PF 
Hirose 
Electric 
Contact 
CD-PC-111 
Hirose 
Electric 
Connector case 
HDE-CTH 
Hirose 
Electric 
Wire material   
B-22(19)X2SJ-1X9 
Sumitomo 
Denko 
(4)
Crimp terminal     
V1.25-4 
J. S. T 
 
 
Maximum cable length: 30m
Skip signal input 
Control 
unit side 







Case GND plate
SKIP0 
SKIP0* 
SKIP1 
SKIP1* 
SKIP2 
SKIP2* 
SKIP3 
SKIP3* 
SKIP0 
SKIP0*
SKIP1 
SKIP1*
SKIP2 
SKIP2*
SKIP3 
SKIP3*
Connection diagram 
 
 
 
Manufacturing precautions   
(1)  The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing 
they are compatible with the specifications. 
(2) Attach the nameplate (with protective cover stamped with the cable name) in the position 
designated in the assembly drawing.   
(3)  Fold the wire material shield on the control unit side over the sheath, and wrap copper foil tape 
over it. Connect to the connector case GND plate.   
(4)  Stamp the name of each signal on the crimp terminal side mark tube and install. 
(5)  Insulate the crimp terminals of unused signal wires with vinyl tape, etc.