6.9  Connection of FCUA-DX10
†/13†/14†  Unit and Machine Control Signal 
 
 
I - 
64
 
6.9  Connection of FCUA-DX10 
† /13 † /14 † Unit and Machine Control Signal 
Input Output 
Type of machine input/output 
signal and No. of points 
32 points
32 points
 
DO-L
R300 cable/
R301 cable 
DI-L
R300 cable/
R301 cable 
Machine 
signal 
FCUA-DX10† 
or 
FCUA-DX13† 
or 
FCUA-DX14† 
Machine 
signal 
 
The remote I/O unit cable types include the R300 and R301 cables. The R300 cable has one end cut off, 
and the R301 cable is used for connection to the Izumi Denki terminal block BX1F-T40A (Note 1). The 
R300-3M and R301-3M cables are available. If a cable longer than 3m is required, use the CN300 and 
CS301 connector set. 
The CN300 connector set (optional, with one end) includes the DI-L and DO-L connectors. The CS301 
connector set (optional, with both ends) includes the DI-L and DO-L connectors, and two connectors for 
connection with the terminal block (Izumi Denki). 
(Note 1)  Izumi Denki I/O terminal BX1F-T40 
<Outline of connection> 
 
24VDC(+) 
24VDC(+) 
Machine 
control panel 
DI-L 
FCUA-DX100/130/140
COM 
A3 
B3
 
B1 
B2 
A1 
A2
 
B1 
B2 
A1 
A2
 
2.2k
Ω 
Input circuit 
sink type 
Output circuit 
sink type 
DO-L 
0V 
RA 
PL 
Control 
circuit 
Stabilized 
power supply
 
DCIN
24VDC(+) 0V FG
1   2   3
RIO2
 
RIO1
 
FG
24VDC(+)
DI-L
FCUA-DX101/131/141
COM 
A3
B3
B1
B2
A1
A2
B1
B2
A1
A2
2.2k
Ω 
Input circuit 
source type 
Output circuit 
source type 
DO-L
0V
RA
PL
DCIN
 
24VDC(+) 0V FG
1   2   3
RIO2
 
RIO1
 
FG
0V
Machine 
control panel
Control 
circuit 
Stabilized 
power supply
 
 
 CAUTION 
 
  Incorrect connections could damage the device, so always connect the cable to the 
designated connector. 
 
  Do not connect or disconnect the connection cables between each unit while the power 
is ON.