Справочник Пользователя для Mitsubishi Electronics C6/C64

Скачать
Страница из 173
6.
 
CONNECTION OF REMOTE I/O UNIT 
6.11  Connection of FCUA-DX12 
† Unit and Machine Control Signal 
 
 
-
 68
 
6.11  Connection of FCUA-DX12 
† Unit and Machine Control Signal 
Input Output 
Analog 
output 
Type of machine input/output 
signal and No. of points 
64 points
48 points
1 point 
 
DO-L
R300 cable/ 
R301 cable 
DI-L
R300 cable/ 
R301 cable 
Machine 
signal
 
FCUA-DX12
†
DCIN
RIO2
RIO1
Machine 
signal
 
DI-R
DO-R
 
The remote I/O unit cable types include the R300 and R301 cables. The R300 cable has one end cut off, 
and the R301 cable is used for connection to the Izumi Denki terminal block BX1F-T40A (Note 1). The 
R300-3M and R301-3M cables are available. If a cable longer than 3m is required, use the CN300 and 
CS301 connector set. 
The CN300 connector set (optional, with one end) includes the DI-L (DI-R) and DO-L (DO-R) 
connectors. The CS301 connector set (optional, with both ends) includes the DI-L and DO-L connectors, 
and two connectors for connection with the terminal block (Izumi Denki). 
(Note 1)  Izumi Denki I/O terminal BX1F-T40 
<Outline of connection>
 
 
24VDC(+) 
24VDC(+) 
Machine 
control panel 
DI-L/R 
FCUA-DX120
COM 
A3 
B3
 
B1 
B2 
A1 
A2
 
B1 
B2 
A1 
A2 
2.2k
Ω 
Input circuit 
sink type
 
Output circuit 
sink type
 
DO-L/R 
0V
RA 
PL 
24VDC(+)
COM 
A3
B3
B1
B2
A1
A2
B1
B2
A1
A2
2.2k
Ω 
Input circuit 
source type
Output circuit 
source type
 
0V
RA
PL
0V
DI-L/R
DO-L/R
FCUA-DX121
B4 
A4
 
DAC 
220
Ω 
DCIN 
24VDC(+) 0V FG
1   2   3
RIO2
 
RIO1
 
FG
DO-R 
Analog 
output 
B4
A4
DAC 
220
Ω 
Stabilized 
power supply 
DCIN
24VDC(+) 0V FG 
1   2   3
RIO2
 
RIO1
 
FG
DO-R
Control 
circuit 
Stabilized 
power supply 
Control 
circuit 
Machine 
control panel
Analog
output 
 
 CAUTION 
 
  Incorrect connections could damage the device, so always connect the cable to the 
designated connector. 
 
  Do not connect or disconnect the connection cables between each unit while the power 
is ON.