Справочник Пользователя для AT&T 555-230-894

Скачать
Страница из 332
Test the System
8-4
Issue 1  September 1995  
Screen 8-3.
Example System Status Screen for Cabinet 3
NOTE:
See the notes associated with Screen 8-1 on the previous page.
NOTE:
In the example of Screen 8-3, cabinet 3 (the second Expansion Port 
Network (EPN)) is not connected to the system. 
Check Circuit Pack Configuration
The list configuration report provides a list of circuit packs plugged into the 
system and recognized by the software.
1. Verify the screen displays:
command:
2. Type list configuration all and press 
ENTER
.
3. Verify the screen displays list configuration screens similar to the example 
shown below. Check the report on the screen with the equipment installed 
and make sure the software is communicating with each circuit pack 
(except power supply circuit packs).  Wait until after the diagnostic tests 
later in this chapter before attempting to correct any problems.
 status system all-cabinets                               Page   3 of   3   SPE A
 SYSTEM STATUS CABINET 3
                            SELECT  SPE ALARMS    TONE/  SERVICE SYSTEM  SYSTEM
 SPE  MODE                  SWITCH  MAJOR MINOR   CLOCK  STATE   CLOCK   TONE
 1A   active                 auto     1    0       3A
 1B   maint/init             auto     1    0       3B
     SERVICE   CONTROL  DEDICATED         SERVICE  BUS ALARMS    BUS   OPEN BUS
 TDM  STATE    CHANNEL    TONES      PKT   STATE  MAJOR MINOR   FAULTS  LEADS
 3A
 3B
 EMERGENCY     SELECT                    SERVICE              CABINET
 TRANSFER      SWITCH      EXP-LINK      STATE     MODE       TYPE
 3A                             -