Installation 
8
3A2798D
Installation
General Information
NOTE: Reference numbers and letters in parentheses 
in the text refer to the callouts in the figures.
Accessories are available from Graco. Make certain all 
accessories are adequately sized and pressure-rated to 
meet the system’s requirements.
Location 
 
Attach a lifting sling at the proper lift spots. Lift off the 
pallet using a crane or a forklift.
Position the ram so the air controls are easily accessi-
ble. Ensure that there is enough space overhead for the 
ram to raise fully. See Dimensions, page 31
Set the brake on the cart before using the system.
Model 16P957 only: Using the holes in the ram base as 
a guide, drill holes for 1/2 in. (13 mm) anchors.
Model 16P957 only: Ensure that the ram base is level in 
all directions. If necessary, level the base using metal 
shims. Secure the base to the floor using 1/2 in. (13 
mm) anchors that are long enough to prevent the ram 
from tipping.
Grounding
Pump: use the supplied ground wire and clamp. Con-
nect other end of wire to a true earth ground. See F
IG
. 5.
Air and fluid hoses: use only electrically conductive 
hoses with a maximum of 500 ft. (150 m) combined 
hose length to ensure grounding continuity. Check elec-
trical resistance of hoses. If total resistance to ground 
exceeds 25 megohms, replace hose immediately.
Air compressor: follow manufacturer’s recommenda-
tions.
Spray gun/dispense valve:
 
ground through connection 
to a properly grounded fluid hose and pump.
Fluid supply container: follow local code.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local code. 
Use only conductive metal pails that are properly 
grounded.
To maintain grounding continuity when flushing or 
relieving pressure: 
hold metal part of the dispense 
valve firmly to the side of a grounded metal pail, then 
trigger the valve.
F
IG
. 4
ti20230b
Lift location
Lift location
Floor 
mounting 
location
Floor 
mounting 
location
The equipment must be grounded to reduce the risk 
of static sparking.  Static sparking can cause fumes 
to ignite or explode.  Grounding provides an escape 
wire for the electric current.
F
IG
. 5
ti8250a