Справочник Пользователя для Mitsubishi Electronics QD75P4

Скачать
Страница из 860
 
 
 
9 - 118 
MELSEC-Q
9   MAJOR POSITIONING CONTROL 
 
9.2.22 LOOP 
The LOOP is used for loop control by the repetition of LOOP to LEND.   
 
 Operation 
 
The LOOP to LEND loop is repeated by set repeat cycles. 
 
  Positioning data setting examples 
 
The following table shows the setting examples when "LOOP" is set in positioning 
data No. 1 of axis 1. 
 
Setting item 
Setting example
Setting details 
Axis 
1   Po
sitioning 
data 
N
o. 
 Da.1   Operation pattern 
– 
Setting not required. (Setting value is ignored.) 
 Da.2   Control system 
LOOP 
Set the LOOP. 
 Da.3   Acceleration time 
No. 
– 
Setting not required. (Setting value is ignored.) 
 Da.4   Deceleration time 
No. 
– 
Setting not required. (Setting value is ignored.) 
 Da.5   Axis to be 
interpolated 
– 
Setting not required. (Setting value is ignored.) 
 Da.6   Positioning address/ 
movement amount 
– 
Setting not required. (Setting value is ignored.) 
 Da.7   Arc address 
– 
Setting not required. (Setting value is ignored.) 
 Da.8   Command speed 
– 
Setting not required. (Setting value is ignored.) 
 Da.9   Dwell time 
– 
Setting not required. (Setting value is ignored.) 
 Da.10   M code 
Set the LOOP to LEND repeat cycles. 
 
        Refer to Section 5.3 "List of positioning data" for information on the setting details.   
 
 Restrictions 
 
(1) An error "Control system LOOP setting error" (error code: 545) will occur if a 
"0" is set for the repeat cycles. 
 
(2) Even if LEND is absent after LOOP, no error will occur, but repeat processing 
will not be carried out. 
(3) Nesting is not allowed between LOOP-LEND's. If such setting is made, only the 
inner LOOP-LEND is processed repeatedly. 
 
POINT 
 
The setting by this control system is easier than that by the special start "FOR loop" of "High-level 
Positioning Control" (refer to CHAPTER 10). 
<Setting data> 
• For special start: Positioning start data, special start data, condition data, and positioning data 
• For control system: Positioning data 
For the special start FOR to NEXT, the positioning data is required for each of FOR and NEXT 
points.    For the control system, loop can be executed even only by one data. 
Also, nesting is enabled by using the control system LOOP to LEND in combination with the special 
start FOR to NEXT. 
However LOOP to LEND cannot be set across block. Always set LOOP to LEND so that the 
processing ends within one block. 
(For details of the "block", refer to Section 10.1 "Outline of high-level positioning control".)