Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
5 - 15 
MELSEC-Q
5      DATA USED FOR POSITIONING CONTROL 
 
5.1.8 Types and roles of control data 
Operation of the positioning system is achieved through the execution of necessary 
controls.    (Data required for controls are given through the default values when the 
power is switched ON, which can be modified as required by the sequence program.) 
Controls are performed over system data or machine operation. 
 
  Controlling the system data : 
 
Performs write/initialization, etc. of the QD75 "setting data". (the system control 
data  Cd.1  and  Cd.2 ) 
 
  Controlling the operation : 
 
Setting operation parameters, changing speed during operation, interrupting or 
restarting operation (the system control data   Cd.41   and   Cd.42 , and the axis 
control
 data
  Cd.3  to  Cd.40 
 
 
[1]   Controlling the system data 
 
  Setting and resetting the setting data 
 
Control details 
Controlled data item 
Write setting data from buffer memory to flash ROM 
 Cd.1 
Flash ROM write request 
Reset (initialize) parameters 
 Cd.2 