Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
1 - 22 
MELSEC-Q
1   PRODUCT OUTLINE 
 
1.2.4 Outline of restarting 
When a stop cause has occurred during operation with position control causing the 
axis to stop, positioning to the end point of the positioning data can be restarted from 
the stopped position by using the "   Cd.6   Restart command". 
If issued during a continuous positioning or continuous path control operation, the 
restart command will cause the positioning to be re-executed using the 
current position (pointed by the positioning data No. associated with the 
moment when the movement was interrupted) as the start point. 
 
 When " 
 Cd.6 
  Restart command" is ON 
 
(1)  If the "   Md.26   Axis operation status" is "Stopped", positioning to the end 
point of the positioning data will be restarted from the stopped position 
regardless of the absolute system or incremental system. 
(2)  When "   Md.26   Axis operation status" is not "Stopped", the warning "Restart 
not possible" (warning code: 104) will be applied, and the restart command will 
be ignored. 
 
[Example for incremental system] 
(a)      The restart operation when the axis 1 movement amount is 300, and the 
axis 2 movement amount is 600 is shown below. 
 
Start point
address
Stop position due to stop cause
Designated end 
point position
Axis 1
400
200
100
100
300
700
Axis 2
Stop position due to stop cause
Stop position
after restart
Axis 1
400
200
100
100
300
700
Axis 2
Restart
Operation during
restart
 
 
 Reference 
 
If the positioning start signal [Y10 to Y13]/external command signal   is turned ON 
while the "   Md.26   Axis operation status" is "Standby" or "Stopped", positioning 
will be restarted from the start of the positioning start data regardless of the 
absolute system or incremental system. ( : When the external command signal is 
set to "External positioning start") 
(Same as normal positioning.) 
 
[Example for incremental system] 
(a)      The positioning start operation when the axis 1 movement amount is 300 
and the axis 2 movement amount is 600 is shown below. 
 
Start point
address
Stop position due to stop cause
Designated end 
point position
Axis 1
400
200
100
100
300
700
Axis 2
Stop position due to stop cause
Stop position
after restart
Axis 1
500
200
100
100
300
900
Axis 2
Positioning
start
Operation during
positioning start