Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
11 - 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CHAPTER 11 MANUAL CONTROL 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
The details and usage of manual control are explained in this chapter. 
In manual control, pulse output commands are issued during a JOG operation and an 
inching operation executed by the turning ON of the JOG START signal, or from a 
manual pulse generator connected to the QD75. 
Manual control using a sequence program from the CPU module is explained in this 
chapter. Refer to GX Configurator-QP Operating Manual for an explanation of manual 
control (JOG operation, inching operation and manual pulse generator operation) using 
the peripheral devices. 
   
 
 
11.1  Outline of manual control  ..................................................................................... 11-  2 
 
11.1.1  Three manual control methods ................................................................ 11-    2 
11.2 JOG 
operation 
........................................................................................................ 11-  4 
 
11.2.1  Outline of JOG operation ......................................................................... 11-    4 
 11.2.2 
JOG 
operation 
execution procedure ....................................................... 11-  7 
 
11.2.3  Setting the required parameters for JOG operation ............................... 11-    8 
 
11.2.4  Creating start programs for JOG operation .............................................. 11- 10 
 11.2.5 
JOG 
operation example ............................................................................ 11- 13 
11.3 Inching 
operation .................................................................................................... 11- 16 
 
11.3.1    Outline of inching operation ...................................................................... 11-  16 
 11.3.2 
Inching 
operation 
execution procedure .................................................... 11-  19 
 
11.3.3  Setting the required parameters for inching operation ............................ 11- 20 
 
11.3.4  Creating a program to enable/disable the inching operation ................... 11- 21 
 11.3.5 
Inching 
operation 
example 
........................................................................ 11-  24 
11.4 Manual 
pulse 
generator operation ......................................................................... 11- 26 
 
11.4.1  Outline of manual pulse generator operation ........................................... 11- 26 
 
11.4.2  Manual pulse generator operation execution procedure ......................... 11- 30 
 
11.4.3  Setting the required parameters for manual pulse generator operation . 11- 31 
 
11.4.4  Creating a program to enable/disable the manual pulse generator   
   operation 
 
.................................................................................................. 
11- 
32